Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density, other
Remarks:
CIPAC MT 186, Pour density, Tap density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 October 2014 - 27 October 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
CIPAC MT 186 (Bulk Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
other: Bulk density
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Name of test material (as cited in study report):4-amino-5(ethylsulphonyl)-o-anisic acid
- Physical state:Solid
- Analytical purity: 99.81%
- Lot/batch numberl:MP1032.31


Key result
Type:
pour density
Density:
0.441 g/cm³
Temp.:
20 °C
Key result
Type:
tap density
Density:
0.598 g/cm³
Temp.:
20 °C

Results of bulk density determination:

Test no.

Sample mass

(g)

Pour volume of sample

(mL)

Tapped volume

(mL)

Pour density (g/mL)

Tap density

(g/mL)

1

100.14

225

168

0.445

0.596

2

98.42

225

164

0.437

0.600

 

Average

0.441

0.598

Conclusions:
The pour density of test item was 0.441 g/mL and the tap density 0.598 g/mL.
Executive summary:

The bulk density of the test item was determined in accordance with GLP study and EEC method A3 ( CIPAC MT 186). The pour density was determined to be 0.441 g/mL and the tap density 0.598 g/mL.

Description of key information

Key study: Test method EEC method A3( CIPAC MT 186), GLP study. The pour density was determined to be 0.441 g/mL and the tap density 0.598 g/mL.

Key value for chemical safety assessment

Relative density at 20C:
0.598

Additional information

Key study: The bulk density of the test item was determined in accordance with EEC method A3( CIPAC MT 186).

The pour density was determined to be 0.441 g/mL and the tap density 0.598 g/mL.