Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 May 2012 - 03 September 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Experimental study conducted in GLP compliant lab according to EC and OECD test methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of distribution:
mass based distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of 1,2,2,6,6-pentamethylpiperidin-4-yl hexadecanoate and 1,2,2,6,6-pentamethylpiperidin-4-yl octadecanoate
EC Number:
700-792-4
Molecular formula:
C26H51NO2, C28H55NO2
IUPAC Name:
Reaction mass of 1,2,2,6,6-pentamethylpiperidin-4-yl hexadecanoate and 1,2,2,6,6-pentamethylpiperidin-4-yl octadecanoate
Test material form:
other: white to pale yellow solid
Details on test material:
- Name of test material (as cited in study report): T-1640L
- Physical state: white to pale yellow solid
- Analytical purity: 98.74%
- Purity test date:
- Lot/batch No.: 10121
- Expiration date of the lot/batch: 12 April 2013
- Stability under test conditions: stable
- Storage condition of test material: refrigerated in the dark under dry conditions

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
> 400 µm
Distribution:
88.7 %
No.:
#2
Size:
>= 125 - <= 400 µm
Distribution:
9.6 %
No.:
#3
Size:
>= 75 - <= 125 µm
Distribution:
1 %
No.:
#4
Size:
>= 30 - <= 75 µm
Distribution:
0 %
No.:
#5
Size:
>= 10 - <= 30 µm
Distribution:
0 %
No.:
#6
Size:
<= 10 µm
Distribution:
0 %

Applicant's summary and conclusion

Conclusions:
The results indicated that 0% w/w of T-1640L was smaller than 75 μm.