Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
sub-chronic toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
a short-term toxicity study does not need to be conducted because a reliable sub-chronic (90 days) or chronic toxicity study is available, conducted with an appropriate species, dosage, solvent and route of administration
Cross-reference
Reason / purpose for cross-reference:
reference to other study
Reference
Endpoint:
particle size distribution (granulometry)
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
DIN 55992-1 (Determination of a parameter for the dust formation of pigments and extenders - Part 1: Rotation method)
Deviations:
not specified
GLP compliance:
no
Type of method:
rotating drum method
Type of distribution:
volumetric distribution
Remarks on result:
not measured/tested
Remarks on result:
not measured/tested

Dustiness values

   Test 1  Test 2  Mean
 Total dustiness [mg/g]  13.38  8.82  11.1
 Inhalable fraction [mg/g] 5.12   2.59  3.855
 Thoraic fraction [mg/g]  1.26  0.22  0.74
 Respirable fraction [mg/g]  0.51  0.09  0.3

The inhalable fraction was only determined up to an airodynamic diameter of 100 µm.

Conclusions:
Dustiness values
 
 Total dustiness [mg/g]: 11.1
 Inhalable fraction [mg/g]:  3.855
 Thoraic fraction [mg/g]: 0.74
 Respirable fraction [mg/g]: 0.3
The inhalable fraction was only determined up to an airodynamic diameter of 100 µm.

Data source

Materials and methods

Results and discussion

Target system / organ toxicity

Critical effects observed:
not specified

Applicant's summary and conclusion