Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01/2008 to 12/2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 07072601
- Expiration date of the lot/batch: 26.07.2008

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature 20 ± 5 °C

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: no

FORM AS APPLIED IN THE TEST (if different from that of starting material): powder
Remarks on result:
not measured/tested
Remarks:
only one sieve (125 µm) was used for separation
No.:
#1
Size:
< 125 µm
Distribution:
< 0.1 %
No.:
#2
Size:
> 125 µm
Distribution:
> 99.9 %
Conclusions:
Evaluation of the paticle size of Bromo(hexahydro-2H-azepin-2-onato-N)magnesium showed, that virtually no particles with diameters below 125 µm are present in the substance.

Description of key information

Evaluation of the paticle size of Bromo(hexahydro-2H-azepin-2-onato-N)magnesium showed, that virtually no particles with diameters below 125 µm are present in the substance.

Additional information