Administrative data

First-aid measures

General advice:
Immediately remove any clothing soiled by the product.

If inhaled:
Supply fresh air; consult doctor in case of complaints.

In case of skin contact:
Rinse with warm water.
If skin irritation continues, consult a doctor.

In case of eye contact:
Protect unharmed eye.
Rinse opened eye for several minutes under running water. Then consult a doctor.

If swallowed:
Rinse out mouth and then drink plenty of water.
Seek medical treatment.

Fire-fighting measures

Suitable extinguishing media:
Use fire-extinguishing methods suitable to surrounding conditions.

Special hazards arising from the substance or mixture:
In case of fire, the following can be released:
Carbon monoxide and carbon dioxide

Advice for firefighters, protective equipment:
Do not inhale explosion gases or combustion gases.
Wear self-contained respiratory protective device.

Additional information on firefighting:
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Avoid formation of dust.
Wear protective clothing.

Environmental precautions:
Do not allow to enter sewers/ surface or ground water.

Methods and material for containment and cleaning up:
Pick up mechanically.
Send for recovery or disposal in suitable receptacles.

Reference to other sections:
For information on safe handling, see safe handling section.
For information on personal protection equipment, see personal protection section.
For information on disposal, see disposal section.

Handling and storage

Advice on safe handling:
Prevent formation of dust.
Thorough dedusting.

Advice on protection against fire and explosion:
Dust can combine with air to form an explosive mixture.

Storage space and container requirements:
No special requirements.

Hints on storage assembly:
Not required.

Storage specifications:
Store in cool, dry conditions in well sealed receptacles.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Void
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Void
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Void
Shipping information
Proper shipping name and description:
Void
Chemical name:
Ferric Citrate
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Void
Shipping information
Proper shipping name and description:
Void
Chemical name:
Ferric Citrate
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Respiratory protection:
Use suitable respiratory protective device in case of insufficient ventilation.

Hand protection:
Protective gloves

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/the chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the
degradation

Material of gloves:
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.

Penetration time of glove material:
The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye protection:
Tightly sealed goggles.

Skin and body protection:
Apron.

General protective and hygiene measures:
The usual precautionary measures are to be adhered to when handling chemicals.
Keep away from foodstuffs, beverages and feed.
Do not eat, drink, smoke or sniff while working.
Be sure to clean skin thoroughly after work and before breaks.

Engineering measures:
Ensure adequate ventilation, especially in confined areas.

Stability and reactivity

Reactivity:
No further relevant information available.

Chemical stability
Thermal decomposition / conditions to be avoided:
No decomposition if used and stored according to specifications.

Possibility of hazardous reactions:
No dangerous reactions known.

Conditions to avoid:
No further relevant information available.

Incompatible materials:
No further relevant information available.

Hazardous decomposition products:
In case of fire, the following can be released:
Carbon monoxide and carbon dioxide

Disposal considerations

Waste treatment methods
Recommendation:
Smaller quantities can be disposed of with household waste.

Uncleaned packaging
Recommendation:
Disposal must be made according to official regulations.

Recommended cleansing agents:
Water, if necessary together with cleansing agents.