Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Iron citrate
EC Number:
219-045-4
EC Name:
Iron citrate
Cas Number:
2338-05-8
Molecular formula:
C6H8O7.xFe
IUPAC Name:
iron citrate
Specific details on test material used for the study:
Name Ferric citrate monohydrate
Batch no. 45882
Appearance red to brown solid powder
Composition Ferric Citrate
Purity 99.81%
Homogeneity homogeneous
Expiry date 18. May 2019
Storage Room temperature (20 ± 5 °C); Keep away from light

Test animals / tissue source

Species:
human
Strain:
other: The EpiOcularTM tissue consists of normal, human-derived keratinocytes which have been cultured to form a stratified squamous epithelium similar to that found in the human cornea.

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
Approx 50 mg of test material
Duration of treatment / exposure:
After overnight incubation, the tissues were pre-wetted with 20 μL DPBS buffer and the tissues were incubated at 37 ± 1 °C, 5 ± 1 % CO2 and ≥ 95% relative humidity for 29 minutes. After that, 50 μL of the controls and a defined amount of the test item were applied in duplicate in one- minute- intervals.
After dosing the last tissue, all plates were transferred into the incubator for 6 hours at 37 ± 1 °C, 5 ± 1 % CO2 and ≥ 95% relative humidity
Duration of post- treatment incubation (in vitro):
At the end of exposure time, the inserts were removed from the plates in one-minute-intervals using sterile forceps and rinsed immediately. The inserts were thoroughly rinsed with DPBS. Then, the tissues were immediately transferred into 5 mL of assay medium in pre-labelled 12-well plate for 25 minutes post soak at room temperature.
After that, each insert was blotted on absorbent material and transferred into a pre-labelled 6-well plate, containing 1 mL assay medium. For post-treatment incubation, the tissues were incubated for 18 hours and 15 minutes at 37 ± 1 °C, 5 ± 1 % CO2 and ≥ 95% relative humidity.
Number of animals or in vitro replicates:
Duplicates

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
other: % tissue viability
Run / experiment:
1
Value:
27.6
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
positive indication of irritation
Irritation parameter:
other: % tissue viability
Run / experiment:
2
Value:
24.4
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
positive indication of irritation
Other effects / acceptance of results:
After treatment with the test item, the mean value of relative tissue viability was reduced to 26.0 %. This value is below the threshold for eye irritation potential (≤ 60%).
All validity criteria were met. The criterion for optical density of the negative control was fulfilled: The OD value was 1.6 (> 0.8 and < 2.5).
The positive control induced a decrease in tissue viability as compared to the negative control to 39.5%. Variation within the replicates of the controls and the test item was acceptable (< 20%).
For these reasons, the result of the test is considered valid.

Any other information on results incl. tables

Mean % tissue viability for the positive control (methyl acetate, which is eye irritant Cat 2) was measured at 39.5%

Applicant's summary and conclusion

Interpretation of results:
study cannot be used for classification
Remarks:
Only indicative of eye irritation / damage
Conclusions:
After treatment with the test item, the mean value of relative tissue viability was 26.0 %.
This value is below the threshold for eye irritation potential (≤ 60%). Test items that induce values below the threshold are either eye irritant or inducing serious eye damage.
According to the OECD Guideline 492, the EpiOcularTM Eye Irritation Test does not allow discrimination between eye irritation/reversible effects on the eye (Category 2) and serious eye damage/irreversible effects on the eye (Category 1). For these purposes, further testing with other suitable test methods is required.
Under the conditions of the test, Ferric citrate monohydrate is considered either eye irritant or inducing serious eye damage in the EpiOcularTM Eye Irritation Test.
However, it has been assessed that ferric citrate should be classified as Eye Irrit. 2 without further testing, based on the fact that it is unlikely to be Eye Dam 1, when citric acid, as the parent acid, is only Eye Irrit 2