Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 Jul- 9 Sep 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point/Boiling Range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Hess. Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(2,2,4-trimethyl-1,2-dihydroquinolin-1-yl)ethan-1-one
EC Number:
665-911-3
Cas Number:
5855-23-2
Molecular formula:
C14 H17 N O
IUPAC Name:
1-(2,2,4-trimethyl-1,2-dihydroquinolin-1-yl)ethan-1-one

Results and discussion

Boiling point
Boiling pt.:
>= 290 - <= 295 °C
Atm. press.:
1 013.3 hPa
Decomposition:
ambiguous
Remarks:
possibly under decomposition

Any other information on results incl. tables

Two DSC measurements in aluminium crucibles with a hole showed an endothermal effect in the temperature range of 230 - 350 °C. The onset temperature (see Table below) was derived from the intersection of the tangent line with the highest slope of the endothermal peak with the baseline. No further endothermal or exothermal effects were observed up to the final temperature (500 °C). The mass loss after the DSC measurements amounted to 100 %; however both measurements showed a few residues indicating a decomposition (see also report M-754109-01-1 linked to chapter 4.14 Explosiveness of this IUCLID dossier). The results of the DSC measurements are summarized in Table below:

Ident No. Test item / mg Starting temp / °C Final test temp / °C Temp. range (endothermal) / °C Onset (boiling) /°C Crucible Observations after the measurement
39149 16.25 -80 500 230 - 350 290.72 Aluminium with a hole Few grey residues, Mass loss: 100 %
39154 17.92 25 500 240 - 340 294.59 Aluminium with a hole Few grey residues, Mass loss: 100 %

The test item had a boiling range at atmospheric pressure (1013.3 hPa) of 290 - 295 °C (possibly under decomposition).