Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 Aug - 11 Aug 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Hessisches Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany
Type of method:
OECD harmonised ring method

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(2,2,4-trimethyl-1,2-dihydroquinolin-1-yl)ethan-1-one
EC Number:
665-911-3
Cas Number:
5855-23-2
Molecular formula:
C14 H17 N O
IUPAC Name:
1-(2,2,4-trimethyl-1,2-dihydroquinolin-1-yl)ethan-1-one

Results and discussion

Surface tension
Surface tension:
57.2 mN/m
Temp.:
20 °C
Conc.:
92 mg/L
Remarks on result:
other: 90 % of the saturation concentration. The concentrations of the two solutions were determined by HPLC analyses (results: 86 mg/L for Test solution 1 and 98 mg/L for Test solution 2).

Any other information on results incl. tables

Individual Results of the Determination of the Concentration by HPLC
The HPLC data of the two solutions (Test solution 1 and Test solution 2) of the test item (HPLC dilution factor 10) are given in the Table below.

Table HPLC data: determination of the test item concentration

Name Amount
Reference
mg/L
Area
mAU*min
Dilution
Factor
Slope
(C1)
Slope Used
(C1)
Content
mg/L
Mean
mg/L
Reference-2 Dil.1 12.252 7.248835278   0.59160568      
Reference-2 Dil.1 12.252 7.25669402   0.59228649 0.59194608    
Testsolution 1 Dil 1 Resp   5.09064629 10   0.59194608 85.9985  
Testsolution 1 Dil 1 Resp   5.07856804 10   0.59194608 85.7944 85.8965
Testsolution 2 Dil 1 Resp   5.78791377 10   0.59194608 97.7777  
Testsolution 2 Dil 1 Resp   5.78519753 10   0.59194608 97.7318 97.7548
blank   not detected 10        
blank   not detected 10        

Results (rounded): 86 mg/L (Test solution 1)

98 mg/L (Test solution 2)

 

Slope = Peak Area (Reference)/ Amount Reference (mg/L)

Content (mg/L) = (Peak Area (Sample) x Dil. factor)/ Slope (Mean Group)

Slope (Mean Group) = Mean value of slope factors (Group)

Individual Results of the Measurement of the Surface Tension
The surface tension values of the two aqueous solutions of the test item were determined.  The measurement was carried out at 20 °C ± 0.5 °C.
A correction factor (Harkins & Jordan) is included. 
The age of the test solutions at the beginning of the measurement was 28.75 hours for the Test solution 1 and 30.0 hours for the Test solution 2. The age of the test solution is defined as the period of time from the preparation of the solution to the recording of the surface tension value. The measured data are given in Table below.

Table: Surface tension of test item, technical substance, measured data

  Experiment 1 Experiment 2
  Time [s]

σM [mN/m]

Time [s] σM [mN/m]
1. measurement 73.5 57.22 71.6 55.99
2. measurement 114.2 57.19 112.8 55.89
3. measurement 156.7 57.18 154.6 55.86
4. measurement 194.1 57.20 194.4 55.87
5. measurement 236.4 57.17 237.9 55.86
6. measurement 278.5 57.17 281.1 55.86
7. measurement 321.5 57.13 321.6 55.86
8. measurement 364.4 57.13 364.7  55.85
9. measurement 408.4 57.12 407.3 55.85
10. measurement 451.4 57.13 450.0 55.85
Mean σM [mN/m]
57.16   55.87

Mean (experiments 1 and 2): σmean = 56.52 mN/m

Standard deviation: 0.91 mN/m

Relative standard deviation: 1.6 %

The mean value, multiplied by the calibration factor (F=1.0125) results in:
σ = σmean · F = 57.2 mN/m

Final Result
The surface tension of two aqueous solutions of test item, technical substance, was determined using the OECD harmonized ring method according to the OECD Guideline 115 and European Commission Council Regulation (EC) No 440/2008, Annex, Part A, method A.5.

The solubility of the test item in water is below 1 g/L (178 mg/L in distilled water at 20 °C, flask method).
According to the OECD Guideline and the EC Regulation saturated solutions were prepared and then diluted to 90 % of the saturation concentration. The concentrations of the two solutions were determined by HPLC analyses (results: 86 mg/L for Test solution 1 and 98 mg/L for Test solution 2).

The surface tension of the aqueous solution of test item, technical substance, was: σ  = 57.2 mN/m at 20 °C

Applicant's summary and conclusion