Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 17, 2006
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study to Japanese guidelines.
Qualifier:
according to guideline
Guideline:
ISO No., other: Japanese Industrial Standards (JIS) K2265-1996
Deviations:
no
GLP compliance:
not specified
Type of method:
other: The flash point determination test was performed according to the Tag closed cup method and the Cleveland open cup method, verification tests for Hazardous Material Type 4 designated under Japans Fire Defense Law. The specifics of the measuring procedure
Flash point:
223 °C
Atm. press.:
1 025 hPa

The test results are shown in the table below.

Sample

Test method

Measurement

Flash point (°C)

Measured value

Mean value

Corrected value*

Silicone monomer L1 (5B)

Lot No. 105-06306-1

Tag closed cup method

First test

Not determined#

Not determined

Not determined

Second test

Not determined

Cleveland Open cup method

First test

222.0

223.0

223.0

Second test

224.0

* The corrected value denotes the mean value adjusted for atmospheric pressure.

# As the sample did not ignite after reaching the upper test temperature limit for the Tag closed cup method of 92°C, the flash point was assigned as “not determined”.

During the Cleveland open cup method flash point test, smoke began to arise from the sample at around 150°C, however, no phenomenon, such as boiling or foaming, was observed even at the flash point. After the test, the sample had turned yellow and become extremely viscous.

Conclusions:
Flash point determined as 223°C
Executive summary:

The flash point determination test on the sample was performed according to the Tag closed cup method and the Cleveland open cup method, verification tests for Hazardous Material Type 4 designated under Japan's Fire Defense Law.

The flash point was determined to be 223°C.

During the Cleveland open cup method flash point test, smoke began to arise from the sample at around 150°C, however, no phenomenon, such as boiling or foaming, was observed even at the flash point. After the test, the sample had turned yellow and become extremely viscous.

Description of key information

The flash point of the substance was determined to be 223°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
223 °C

Additional information

The flash point determination test on the sample was performed according to the Tag closed cup method and the Cleveland open cup method, verification tests for Hazardous Material Type 4 designated under Japan's Fire Defense Law.

The flash point was determined to be 223°C.

During the Cleveland open cup method flash point test, smoke began to arise from the sample at around 150°C, however, no phenomenon, such as boiling or foaming, was observed even at the flash point. After the test, the sample had turned yellow and become extremely viscous.