Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020-01-31
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The substance cannot be ignited by the hot flame of a small gas burner (burning number BZ = 1). Instead, the substance melts and the colour turned to black. Therefore, the full burning rate test is not required.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item is not a flammable solid of class 4.1.
Executive summary:

The substance cannot be ignited by the hot flame of a small gas burner (burning number BZ = 1). Instead, the substance melts and the colour turned to black. Therefore, the full burning rate test is not required. The substance is not a flammable solid of Division 4.1 and has not to be labelled as such a substance.

Description of key information

The substance cannot be ignited by the hot flame of a small gas burner (burning number BZ = 1). Instead, the substance melts and the colour turned to black. Therefore, the full burning rate test is not required. The substance is not a flammable solid of Division 4.1 and has not to be labelled as such a substance.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification