Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
adsorption / desorption: screening
Remarks:
adsorption
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Remarks:
The substance is not fully compliant with the applicability domain of the model. However, this calculation is used in a weight of evidence approach, in accordance with the REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2. It is adequately documented and justified: the prediction is evaluated on the basis of the model performance on similar substances. For more details see section `overall remarks, attachments´.
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOCWIN v2.00

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACh Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOCWIN v2.00, MCI based method
Full reference and details of the used formulas can be found in:
Meylan, W., P.H. Howard and R.S. Boethling, "Molecular Topology/Fragment Contribution Method for Predicting Soil Sorption Coefficients", Environ. Sci. Technol. 26: 1560-7 (1992)
- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justific ation for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: calculation
Media:
soil
Details on test conditions:
BASIS FOR CALCULATION OF Koc:
- Estimation software: EPI Suite™ v 4.11, KOCWIN v2.00, MCI based method
- Water solubility: < 0.54 mg/L
- Vapour pressure: 1.2E-07 hPa
Type:
Koc
Value:
77 400 000 L/kg
Temp.:
25 °C
Type:
log Koc
Value:
7.89 dimensionless
Temp.:
25 °C

For detailed information on the results please refer to the attached report.

Endpoint:
adsorption / desorption: screening
Remarks:
adsorption
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Remarks:
The substance is not fully compliant with the applicability domain of the model. However, this calculation is used in a weight of evidence approach, in accordance with the REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2. It is adequately documented and justified: the prediction is evaluated on the basis of the model performance on similar substances. For more details see section `overall remarks, attachments´.
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOCWIN v2.00

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACh Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOCWIN v2.00, MCI based method
Full reference and details of the used formulas can be found in:
Meylan, W., P.H. Howard and R.S. Boethling, "Molecular Topology/Fragment Contribution Method for Predicting Soil Sorption Coefficients", Environ. Sci. Technol. 26: 1560-7 (1992)
- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justific ation for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: calculation
Media:
soil
Details on test conditions:
BASIS FOR CALCULATION OF Koc:
- Estimation software: EPI Suite™ v 4.11, KOCWIN v2.00, MCI based method

Type:
Koc
Value:
403 300 L/kg
Temp.:
25 °C
Type:
log Koc
Value:
5.61 dimensionless
Temp.:
25 °C

For detailed information on the results please refer to the attached report.

Endpoint:
adsorption / desorption: screening
Remarks:
adsorption
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Remarks:
The substance is not fully compliant with the applicability domain of the model. However, this calculation is used in a weight of evidence approach, in accordance with the REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2. It is adequately documented and justified: the prediction is evaluated on the basis of the model performance on similar substances. For more details see section `overall remarks, attachments´.
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOCWIN v2.00

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACh Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOCWIN v2.00, MCI based method
Full reference and details of the used formulas can be found in:
Meylan, W., P.H. Howard and R.S. Boethling, "Molecular Topology/Fragment Contribution Method for Predicting Soil Sorption Coefficients", Environ. Sci. Technol. 26: 1560-7 (1992)
- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justific ation for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: calculation
Media:
soil
Details on test conditions:
BASIS FOR CALCULATION OF Koc:
- Estimation software: EPI Suite™ v 4.11, KOCWIN v2.00, MCI based method
Type:
Koc
Value:
10 000 000 000 L/kg
Temp.:
25 °C
Type:
log Koc
Value:
15.09 dimensionless
Temp.:
25 °C

For detailed information on the results please refer to the attached report.

Description of key information

log Koc = 5.61 – 15.09 (constituents 1 - 3, KOCWIN v2.00, MCI)

log Koc = 2.73 - 2.84 (constituent 1-3, KOCWIN v2.00, log Pow method)

Key value for chemical safety assessment

Additional information

There is no experimental study available, in which the adsorption coefficient of Hexamethylene diisocyanate, trimers, reaction products with 2-hydroxyethyl acrylate (CAS 162492-01-5) was assessed. Therefore, the adsorption coefficient was calculated by (Q)SAR, using the MCI and log Pow based methods of the KOCWIN v2.00 model (EPI Suite v4.11).

 

Since the substance is a UVCB, the adsorption coefficient was estimated for the three main constituents of the substance. The log Pow is a required input parameter for the log Pow based method. An experimental log Pow of 4.23 (OECD 117, HPLC method) is available, which was measured for the whole substance and presumably most accurately reflects the log Pow of constituent 1, the predominant constituent of the substance.

 

The three constituents only partially fall within the applicability domains of the models due to their high molecular weights (730.25 - 1305.43 g/mol) and the too frequent occurrence of certain structural domains (Urea, aliphatic Nitrogen to Carbon). Therefore, the result is used in a weight of evidence approach, in accordance with REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2.

The estimated log Koc values based on the MCI method are 7.79 (constituent 1), 5.61 (constituent 2), and 15.09 (constituent 3), respectively. The estimated log Koc values obtained by the log Pow based method using the experimentally determined log Pow are 2.82 (constituent 1), 2.84 (constituent 2), and 2.73 (constituent 3), respectively. Thus, the substance potentially has a tendency to adsorb to sediment and soil particles.