Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 May 2004 to 19 May 2004.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2004

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes
Type of method:
static method

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): S178207
- Physical state: White powder
- Analytical purity: 75.1%
- Lot/batch No.: SBT-5-0254
- Expiration date of the lot/batch: March 31st 2005
- Stability under test conditions: Stable
- Storage condition of test material: At room temperature on the dark

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
0.11 Pa
Remarks on result:
other: 8.3E-04 mm Hg
Transition / decomposition
Transition / decomposition:
no

Any other information on results incl. tables

Table 1 Vapour pressure of S178207 at 3 different temperatures

Measurement

Temperature

Mean vapour pressure ±

2 x calculated error [pa]

[°C]

[K]

p

ln p

16 – 26

37.42

310.57

1.93 ± 0.01

0.66 ± 0.01

29 - 36

32.24

305.39

0.828 ± 0.007

-0.19 ± 0.01

39 - 49

25.62

298.77

0.291 ± 0.003

-1.23 ± 0.01

Applicant's summary and conclusion

Conclusions:
Using the Static Technique, the vapour pressure of S178207 at 20°C is:
0.11 ± 0.01 Pa = 8.3±0.8 E-04 mm Hg
Executive summary:

The determination of the vapour pressure of S178207 was performed in accordance with the following guidelines:

European Economic Community (EEC), EEC directive 92/69/EEC, Part A, Methods for the determination of physico-chemical properties, A.4 "Vapour pressure"

and

Organisation for Economic Co-operation and Development (OECD), OECD Guidelines for the Testing of Chemicals, Guideline No. 104.

Using the Static Technique, the vapour pressure of S178207 at 20°C is: 0.11 ± 0.01 Pa = (8.3±0.8) E-04 mm Hg