Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07Jan2019 to 05Jun2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl 1-methyl-4-[(methylphenylhydrazono)methyl]pyridinium sulphate
EC Number:
269-503-2
EC Name:
Methyl 1-methyl-4-[(methylphenylhydrazono)methyl]pyridinium sulphate
Cas Number:
68259-00-7
Molecular formula:
C14H16N3.CH3O4S
IUPAC Name:
methyl 1-methyl-4-[(methylphenylhydrazono)methyl]pyridinium sulphate
Test material form:
solid: particulate/powder
Details on test material:
Batch 1065826
Specific details on test material used for the study:
Batch (Lot) Number: 1065826
Expiry date: 13 November 2021 (expiry date)
Physical Description: Yellow powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
ca. 2 s

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The preliminary screening test was performed for the determination of the flammability of the test item.

No propagation of combustion of the test item along 200 mm length of the pile within 2 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not flammable’.
Executive summary:

The preliminary screening test was performed for the determination of the flammability of the test item.

The flame of the gas burner did ignite the test item pile. The test item melted, burned with a orange flame, emitted orange sparks, expanded and turned into a black residue. Grey smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed.

No propagation of combustion of the test item along 200 mm length of the pile within 2 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not flammable’.