Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Principles of method if other than guideline:
Malvern laser diffraction
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Test material form:
solid

Results and discussion

Any other information on results incl. tables

Ca. 10 % [w/w] of the test substance were found to have a diameter of > 250 µm. This fraction was separated by sieving prior to the measurement.

For the remaining fraction a median diameter of 60 µm was determined. Ca. 5 % thereof had a diameter < 10 µm.

Applicant's summary and conclusion

Conclusions:
Ca. 10 % [w/w] of the test substance were found to have a diameter of > 250 µm.
For the remaining fraction a median diameter of 60 µm was determined. Ca. 5 % thereof had a diameter < 10 µm.