Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 Feb - 4 March 2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1 with evaluation according to Fraunhofer
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
other: laser diffraction
Key result
Percentile:
D10
Mean:
99 µm
St. dev.:
0
Remarks on result:
other: Based on 2 measurements
Key result
Percentile:
D50
Mean:
206 µm
St. dev.:
0
Remarks on result:
other: Based on 2 measurements
Key result
Percentile:
D90
Mean:
379 µm
St. dev.:
0
Remarks on result:
other: Based on 2 measurements
Size:
< 10 µm
Distribution:
0 %
Remarks on result:
other: Number was not specified
Conclusions:
The particle size distribution of the substance was determined by laser diffraction analysis. 0% is< 10.00 µm; 10% is < 99 µm; 50% is < 206 µm and 90% is < 379 µm.
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Company data with limited information.
Qualifier:
no guideline followed
Principles of method if other than guideline:
Sieve analysis.
GLP compliance:
no
Type of method:
other: not specified
Percentile:
D50
Remarks on result:
not measured/tested
Size:
> 2.36 mm
Distribution:
12 %
Remarks on result:
other: number not specified
Size:
> 1.7 mm
Distribution:
66 %
Remarks on result:
other: number not specified
Size:
> 1.18 mm
Distribution:
97 %
Remarks on result:
other: number not specified
Size:
> 0.85 mm
Distribution:
99 %
Remarks on result:
other: number not specified
Conclusions:
Sieve analysis showed that 99% of sodium nitrate (prilled form) is > 0.85 mm.

Description of key information

Laser diffraction analysis result for sodium nitrate (crystalline powder): 0% is < 10.00 µm, 10% is < 99 µm, 50%  is < 206 µm and  90% is < 379 µm.  

Sieve analysis result for prilled sodium nitrate:  99% is > 0.85 mm.

Additional information