Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
handbook data, no information is given on test method
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
88 °C
Remarks on result:
other: handbook data, no information is given on pressure
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 Jul 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
other: ASTM D93
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
88 °C
Remarks on result:
other: The pressure 1013 hPa is assumed sinde the pressure should be corrected to 1013 hPa by the system.
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
Handbook data, no information is given on test method
GLP compliance:
not specified
Type of method:
open cup
Flash point:
101.67 - 123.89 °C
Remarks on result:
other: Handbook data; data on pressure was not specified

Published data, no information is given on air pressure

Description of key information

88 °C at 1013 hPa (Pensky-Martens apparatus, ASTM D93)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
88 °C

Additional information

One of the values reported within literature (101 - 123 °C) is slightly higher but anyway the lowest value shall be taken into account for the risk assessment.