Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 November 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: non GLP screening study without detailed documentation.
Justification for type of information:
Determination of appearance by trained personell according to standard inhouse operation procedures.
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
yes
Remarks:
No detailed description of experimental details available. Study was conducted according to an established inhouse ISO method comparable to the OECD 110 as a non-GLP study.
Principles of method if other than guideline:
The test item has a rock like appearance (fragments from solidified molten reaction mass). The measurement of the particle size distribution of the test item is neither technically feasable nor scientifically reasonable. As a surrogate the particle size distribution of a typical solid concentrate (as placed on the market - textile auxiliary) is presented.
GLP compliance:
no
Other quality assurance:
other: ISO method for calibration
Type of method:
sieving
Type of particle tested:
aggregate
Type of distribution:
mass based distribution
Specific details on test material used for the study:
Test item with emulsifier was investigated (as placed on the market).

Source substance:

Amidoamine (UVCB)
Pulcra ID: DE07_2014_012_BEL66
Former chemical name: Amides, from diethylenetriamine and hydrogenated palm oil
Former CAS No.: 1618093-67-6
New chemical name: Triglycerides, C16-18 (even-numbered), reaction products with diethylenetriamine
Physical state: pale yellowish solid at 20 °C
Batch No.: K8 4309 L481
Expiry date of batch: 09 March 2018
Purity: 100 % (UVCB)
Stability: stable under test conditions
Storage condition of test material: Room temperature, protected from light

Target substance:

Amidoamine 2 (UVCB, low nitrogen):
Former chemical name: Amides, from diethylenetriamine and hydrogenated palm oil
CAS No.: 1618093-67-6
New chemical name: Glycerides, C16-18 (even numbered) and their amidation products with diethylenetriamine
Physical state: pale yellowish solid at 20 °C
Batch No.: PU50070067
Purity: 100 % (UVCB)
Storage condition of test material: Room temperature, protected from light
Stability: stable under test conditions
Remarks on result:
not determinable because of methodological limitations
Remarks:
typical solid concentrate was tinvestigated
Key result
Percentile:
D50
Mean:
> 800 µm
Remarks on result:
other: Amidoamine (UVCB) + emulsifier
Remarks:
typical solid concentrate
Key result
Percentile:
other: D98
Mean:
> 800 µm
Remarks on result:
other: Amidoamine (UVCB) + emulsifier
Remarks:
typical solid concentrate
Key result
Percentile:
D99
Mean:
> 800 µm
Remarks on result:
other: Amidoamine 2 (UVCB) + emulsifier
Remarks:
typical solid concentrate
No.:
#1
Size:
ca. 800 µm
Distribution:
ca. 98.5 %
Remarks on result:
other: Amidoamine (UVCB) + emulsifier
Remarks:
typical solid concentrate
No.:
#2
Size:
> 800 µm
Distribution:
100 %
Remarks on result:
other: Amidoamine 2 (UVCB) + emulsifier
Remarks:
typical solid concentrate

Median diameter:       > 800 µm

Mean and standard deviation was not determned in this screening experiment.

Shape of particles:

Solid = rock like appearance

Dispersion = spheres, test item is dispersed/emulsfied in an aqueous solution

Size and distribution (dispersion):

Amidoamine (UVCB):

Mass taken/time:       20g/5 min

    Sieve [µm]    
 mass (g)  %
 > 800  19.7  98.50
 > 400  0.2  0.90
 > 250  0.1  0.45
 > 125  0.0  0.10
 < 125  0.0  0.05
 total  20.0  100.00

Amidoamine 2 (UVCB):

Mass taken/time:       20g/5 min

    Sieve [µm]    
 mass (g)  %
 > 800  20.0  100.00
 > 400  0.0  0
 > 250  0.0  0
 > 125  0.0  0
 < 125  0.0  0
 total  20.0  100.00
Conclusions:
The mass median diameter (MMD) of the test item is calculated to be > 800 µm.
Executive summary:

In the non-GLP Klimisch 2 study the particle size distribution of amidoamine test items in mixtures (solid concentrates including additives as supplied to downstream users were determined by sieving using sieves with a mesh size of 125 to 800 µm. The mass median diameter (MMD) of the test item is calculated to be > 800 µm.

Description of key information

The mass median diameter (MMD) of the test item is calculated to be > 800 µm.


Target and source substances are marketed as solids in prills and flakes form manufactured by pastillation units operating with similar parameters. Therefore solids of Amidoamine 2 (UVCB, low nitrogen) will have a comparable particle size distribution as Amidoamine (UVCB). It is expected that the higher concentration of saturated mono- and diglycerides and the presence of saturated triglycerides in Amidoamine 2 (UVCB, low nitrogen) will have no influence on the particle size distribution (Granulometry).

Additional information