Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 D (Ready Biodegradability: Closed Bottle Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.6 (Degradation: Chemical Oxygen Demand)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
XRD 535 Me
Lot # : GHD-2413-21
Purity: 93.9%
Oxygen conditions:
aerobic
Inoculum or test system:
other: Activated sludge bacteria
Details on inoculum:
- Source of inoculum/activated sludge: The aeration stage of the HRC Limited sewage treatment plant treating predominantly domestic sewage
- Preparation of inoculum for exposure: The sample was allowed to settle and the supernatant filtered through Whatman GFA filter paper (first 250 mL discarded)
Duration of test (contact time):
28 d
Initial conc.:
3 mg/L
Based on:
test mat.
Parameter followed for biodegradation estimation:
DOC removal
Details on study design:
TEST CONDITIONS
- Composition of medium: Standard nutrient medium (solution 1: KH2PO4, K2HPO4, Na2HPO4.2H2O, NH4Cl; solution 2: MgSO4.7H2O; solution 3: CaCl2; Solution 4: FeCl3.6H2O)
- Test temperature: 20 ± 1°C
- Continuous darkness: Yes

TEST SYSTEM
- Culturing apparatus: 280 mL BOD bottles (darkened glass) with ground glass stoppers
- Number of culture flasks/concentration: 2
- Test performed in closed vessels due to significant volatility of test substance: Closed vessels

SAMPLING
- Sampling frequency: 0, 5, 15 or 28 days

CONTROL AND BLANK SYSTEM
- Inoculum blank: Inoculated dilution water; inoculated dilution water and filter paper
- Abiotic sterile control: Non-inoculated dilution water
Reference substance:
benzoic acid, sodium salt
Remarks:
3 mg/L
Reference substance:
aniline
Remarks:
2 mg/L
Test performance:
Oxygen depletions in the inoculated and non-inoculated control series were within the prescribed limits
Key result
Parameter:
% degradation (DOC removal)
Value:
>= 8 - <= 11
Sampling time:
28 d
Details on results:
Oxygen depletion (28 days): 0.375 mgO2/L
Parameter:
ThOD
Value:
4.47 other: mgO2/L
Results with reference substance:
Sodium benzoate attained 81-83% degradation within 28 days.
Aniline attained 59% degradation within 28 days.
Validity criteria fulfilled:
yes
Interpretation of results:
not readily biodegradable
Conclusions:
Not readily biodegradable
Executive summary:

The ready biodegradability of the test substance was assessed using a closed bottle procedure according to EEC directive C6 and OECD guideline 301D.

The test substance attained between 8-11% degradation after 28 days and therefore cannot be termed as readily biodegradable.

The standard substances, sodium benzoate and aniline, attained 81-83% and 59% degradation respectively within 28 days.

Oxygen depletions in the inoculated and non-inoculated control series were within the prescribed limits.

Description of key information

Study Type

 Study Details Value  Guideline Reliability 
Ready Biodegradation Study

Closed bottle method

Not Readily Biodegradable

OECD 301D

EU Method C.6

Key value for chemical safety assessment

Biodegradation in water:
not biodegradable

Additional information