Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Bag 4 - UPZ Mill. Lot # 19/1949
Key result
Percentile:
D10
Mean:
1.64 µm
St. dev.:
0.01
Key result
Percentile:
D50
Mean:
8.81 µm
St. dev.:
0.01
Key result
Percentile:
D90
Mean:
41.49 µm
St. dev.:
0.02
Conclusions:
D10 = 1.64 microns, D50 = 8.81 microns, D90 = 41.49 microns as measured by laser diffraction using a Malvern Mastersizer from a sample of the substance dispersed in water.

Description of key information

D10 = 1.64 microns, D50 = 8.81 microns, D90 = 41.49 microns as measured by laser diffraction using a Malvern Mastersizer from a sample of the substance dispersed in water.

Additional information