Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 242-745-6 | CAS number: 19009-56-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 27 Feb 2017 - 27 Feb 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- Study conducted in accordance with international guidelines and in accordance with GLP. All guideline criteria were met.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- 2-methyldecan-1-al
- EC Number:
- 242-745-6
- EC Name:
- 2-methyldecan-1-al
- Cas Number:
- 19009-56-4
- Molecular formula:
- C11H22O
- IUPAC Name:
- 2-methyldecanal
- Test material form:
- liquid
- Details on test material:
- Appearance: clear, colourless liquid
Constituent 1
Test animals / tissue source
- Species:
- cattle
- Strain:
- not specified
- Details on test animals or tissues and environmental conditions:
- TEST ANIMALS
- Source: Schlachthof Aschaffenburg, 63739 Aschaffenburg, Germany
- Age at study initiation: corneae from at least 9 month old donors
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 0.75 mL
- Concentration (if solution): N/A
VEHICLE -N/A - Duration of treatment / exposure:
- 10 minutes
- Duration of post- treatment incubation (in vitro):
- 2 hours
- Number of animals or in vitro replicates:
- x3 replicates per test group
Following the opacity readings, the permeability endpoint was measured as an indication of the integrity of the epithelial cell sheets. After the final opacity measurement was performed, the complete medium was removed from the anterior compartment and replaced by 1 mL of a 0.4% (w/v) sodium fluorescein solution in HBSS. Corneae were incubated again in a horizontal position for 90 minutes in a water-bath at 32 ± 1 °C. Complete medium from the posterior compartment was removed, well mixed and transferred into a 96 well plate and the optical density at 490 nm (OD490) was determined with a spectrophotometer.
The optical density was measured with a microplate reader (Versamax® Molecular Devices) at 490 nm (OD490). The absorbance values were determined using the software SoftMax Pro Enterprise (version 4.7.1). - Details on study design:
- SELECTION AND PREPARATION OF CORNEAS: Freshly isolated bovine eyes of at least 9 month old donor cattle were collected from the abattoir. Excess tissue was removed from the excised eyes. The isolated eyes were transported to the laboratory in HBSS containing 1% (v/v) Penicillin/Streptomycin (100 units/mL penicillin and 100 µg/mL streptomycin). The corneae were isolated on the same day after delivery of the eyes and were directly used in the BCOP test.
All eyes were carefully examined macroscopically for defects. Those presenting defects such as vascularization, pigmentation, opacity and scratches were discarded. The cornea was carefully removed from the eye using scalpel and rounded scissors. A rim of about 2 mm of tissue (sclera) was left for stability and handling of the isolated cornea.
Each isolated cornea was mounted in a specially designed cornea holder according to the description given in OECD guideline 437, which consists of anterior and posterior compartments, which interface with the epithelial and endothelial sides of the cornea, respectively. The endothelial side of the cornea was positioned against the sealing ring (O-ring) of the posterior part of the holder. The cornea was gently flattened over the O-ring but stretching was avoided. The anterior part of the holder was positioned on top of the cornea and fixed in place with screws. Both compartments of the holder were filled with incubation medium. The posterior compartment was filled first to return the cornea to its natural convex position. Care was taken to assure no air bubbles were present within the compartments.
For equilibration, the corneae in the holder were incubated in a vertical position for about one hour at 32 ± 1 °C in a water-bath.
At the end of the incubation period, the basal opacity was determined (t0).
The basal opacity of all corneae was recorded. Each cornea with a value of the basal opacity > 7 was discarded. Sets of three corneae were used for treatment with the test item and the negative and positive controls.
QUALITY CHECK OF THE ISOLATED CORNEAS: All eyes were carefully examined macroscopically for defects. Those presenting defects such as vascularization, pigmentation, opacity and scratches were discarded.
NUMBER OF REPLICATES: 3 per group
NEGATIVE CONTROL USED: Yes - Saline (0.9% NaCl in deionised water)
SOLVENT CONTROL USED (if applicable) N/A
POSITIVE CONTROL USED: Yes - 2-Ethoxyethanol (purity: 99%)
APPLICATION DOSE AND EXPOSURE TIME: 0.75 mL and 10 minutes incubation
TREATMENT METHOD: [closed chamber / open chamber] Not specified
POST-INCUBATION PERIOD: Yes - two hours
REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: 1 step
- POST-EXPOSURE INCUBATION: After exposure of the corneae to the test groups, corneae were rinsed and incubated for a further two hours
METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: Opacitometer OP_KiT opacitometer (Electro Design, 63-Riom France)
- Corneal permeability: passage of sodium fluorescein dye measured with the aid of [UV/VIS spectrophotometry / microtiter plate reader] (OD490)
- Others (e.g, pertinent visual observations, histopathology): (please specify) The permeability endpoint was measured, as an indication of the integrity of the epithelial cell sheets.
SCORING SYSTEM: In Vitro Irritancy Score (IVIS)
DECISION CRITERIA: please specify if the decision criteria as indicated in the TG was used.
Results and discussion
In vitro
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Value:
- >= 0.67 - <= 1.67
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Remarks:
- >= 0 - <=1
- Positive controls validity:
- valid
- Remarks:
- >=74.67 - <=95.67
- Remarks on result:
- no indication of irritation
- Remarks:
- IVIS score: <= 3
- Irritation parameter:
- in vitro irritation score
- Value:
- 1.02
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Remarks:
- 1.44
- Positive controls validity:
- valid
- Remarks:
- 98.08
Any other information on results incl. tables
Table 1 demonstrates the results of the test groups after 10 minutes incubation.
With the negative control (saline) neither an increase of opacity nor permeability of the corneae could be observed (mean IVIS = 1.44). The positive control (2-Ethoxyethanol) was tested undiluted and showed clear opacity and distinctive permeability of the corneae (mean IVIS = 98.08) corresponding to a classification as serious eye damaging (CLP/EPA/GHS (Cat 1)). The test item was tested undiluted. Relative to the negative control, the test item did not cause an increase of the corneal opacity or permeability. The calculated mean IVIS was 1.02 (threshold for serious eye damage: IVIS > 55). According to OECD 437, the test item is not categorized.
Table 1. Results after 10 minutes incubation time
TEST GROUP |
OPACITY VALUE = DIFFERENCE (t130-t0) OF OPACITY |
PERMEABILITY AT 490 nm (OD490) |
IVIS |
MEAN IVIS |
PROPOSED IN VITRO IRRITANCY SCORE |
||
|
|
MEAN |
|
MEAN |
|
|
|
Negative control |
1 |
0.33 |
0.069 |
0.074 |
2.04 |
1.44 |
Not categorised |
0 |
0.081 |
1.22 |
|||||
0 |
0.072 |
1.08 |
|||||
Positive control |
95.67* |
0.643* |
105.31 |
98.08 |
Category 1 |
||
84.67* |
0.890* |
98.02 |
|||||
74.67* |
1.063* |
90.91 |
|||||
Test item |
0.67* |
-0.009* |
0.53 |
1.02 |
Not categorised |
||
1.67* |
0.011* |
1.83 |
|||||
0.67* |
0.002* |
0.70 |
*corrected values
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The calculated mean in vitro irritancy score was 1.02. Therefore, the test item is not categorized (GHS).
- Executive summary:
The test item was assessed for eye irritation as per OECD Guideline 437, 26 July 2013.
After a first opacity measurement of the fresh bovine corneae (t0), the neat test item, the positive, and the negative controls were applied to corneae fixed in an incubation chamber in horizontal position for 10 minutes at 32 ±1 °C. The posterior chamber contained incubation medium. After the incubation phase the test item, the positive, and the negative controls were each rinsed from the corneae. Further, the corneae were incubated for another 120 minutes at 32 ±1 °C in a vertical position, while the anterior chamber contain incubation medium as well. Afterwards, opacity was measured a second time (t130).
After the opacity measurements permeability of the corneae was determined by measuring spectrophotometrically the transfer of sodium fluorescein after incubation in a horizontal position for 90 minutes at 32 ± 1 °C.
Relative to the negative control, the test item did not cause an increase of the corneal opacity or permeability. The calculated mean IVIS was 1.02 (threshold for serious eye damage: IVIS > 55). According to OECD 437, the test item is not classified for eye irritation.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.