Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1997
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Lasergranulometrie, Malvern Mastersizer X
Version / remarks:
Lasergranulometrie, Malvern Mastersizer X
Principles of method if other than guideline:
Method: Other: according to guideline in Standard Operating Procedure (SOP) 960 of DSM CHEMIE LINZ GmbH 4021 LINZ: Determination of Particle size distribution by using Lasergranulometry, Malvern Mastersizer X.
GLP compliance:
not specified
Type of method:
other: Lasergranulometrie, Malvern Mastersizer X
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
421-690-3
EC Name:
-
Cas Number:
203515-86-0
Molecular formula:
C14H21N3O6 . ClH
IUPAC Name:
5-amino-N1,N3-bis(2,3-dihydroxypropyl)benzene-1,3-dicarboxamide hydrochloride

Results and discussion

Mass median aerodynamic diameter:
16.88 µm
Particle sizeopen allclose all
Percentile:
D10
Mean:
> 0.5 - < 2.9 µm
Remarks on result:
other: No standard deviation was determined in the report.
Percentile:
D50
Mean:
> 2.9 - < 17.1 µm
Remarks on result:
other: No standard deviation was determined in the report.
Percentile:
D90
Mean:
> 17.1 - < 83.3 µm
Remarks on result:
other: No standard deviation was determined in the report.
Percentile:
D95
Mean:
> 83.3 - < 100 µm
Remarks on result:
other: No standard deviation was determined in the report.
Percentile:
D99
Mean:
> 100 - < 151 µm
Remarks on result:
other: No standard deviation was determined in the report.

Any other information on results incl. tables

µm                    %

> 272                0

224 - 272          0,1

183 - 224          0,3

151 - 183          0,7

124 - 151          1,5

100 - 124          2,6

83,3 - 100         3,9

68,3 - 83,3        5,3

56,1 - 68,3        6,1

46,0 - 56, 1       6,2

37,8 - 46,0        5,6

31,0 - 37,8        4,9

25,5 - 31,0        4,3

20,9 - 25,5        4,0

17,1 - 20,9        4,0

14,1 - 17,1        4,2

11,6 - 14,1        4,6

9,48 - 11,6        5,0

7,78 - 9,48        5,3

6,39 - 7,78        5,4

5,24 - 6,39        4,9

4,30 - 5,24        4,3

3,53 - 4,30        3,6

2,90 - 3,53        3,0

2,38 - 2,90        2,5

1,95 - 2,38        2,0

1,60 - 1,95        1,5

1,32 - 1,60        1,6

0,50 - 1,32        2,4

Applicant's summary and conclusion

Conclusions:
The particle size distribution of ABA-HCl has a median diameter of 16.88 µm.