Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1995
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: 92/69/EWG A17
Principles of method if other than guideline:
Method: Other: according to guideline RL 92/69/EWG, Method A17
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
421-690-3
EC Name:
-
Cas Number:
203515-86-0
Molecular formula:
C14H21N3O6 . ClH
IUPAC Name:
5-amino-N1,N3-bis(2,3-dihydroxypropyl)benzene-1,3-dicarboxamide hydrochloride
Constituent 2
Reference substance name:
3,5-bis[(2,3-dihydroxypropyl)carbamoyl]aniliniumchloride
IUPAC Name:
3,5-bis[(2,3-dihydroxypropyl)carbamoyl]aniliniumchloride
Details on test material:
- Name of test material (as cited in study report): ABA-HCl
- Molecular formula (if other than submission substance):
- Molecular weight (if other than submission substance):
- Smiles notation (if other than submission substance):
- InChl (if other than submission substance):
- Structural formula attached as image file (if other than submission substance): see Fig.
- Substance type:
- Physical state: Powder
- Analytical purity: ≥98.5
- Impurities (identity and concentrations):
- Composition of test material, percentage of components:
- Isomers composition:
- Purity test date:
- Lot/batch No.: S-31308
- Expiration date of the lot/batch:
- Radiochemical purity (if radiolabelling):
- Specific activity (if radiolabelling):
- Locations of the label (if radiolabelling):
- Expiration date of radiochemical substance (if radiolabelling):
- Stability under test conditions:
- Storage condition of test material:
- Other:

Results and discussion

Test results (Oxidising solids)open allclose all
Sample tested:
test mixture (not specified)
Parameter:
maximum burning rate
Result:
0.44 mm/s
Sample tested:
reference mixture (not specified)
Parameter:
maximum burning rate
Result:
0.48 mm/s

Any other information on results incl. tables

test mixture (10% substance) dies out at 70 mm

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Remarks:
no oxidising properties
Conclusions:
ABA-HCl has no oxidising properties.