Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 March 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed according to EU A.9 guideline, under GLP, without deviation and with certificate of analysis included.
Reason / purpose for cross-reference:
reference to other study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Remarks:
2017-01-10
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
71 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: First determination
Flash point:
73 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: Second determination
Flash point:
66 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: Third determination
Flash point:
70 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: Fourth determination
Key result
Flash point:
70 °C
Atm. press.:
ca. 101.3 kPa
Remarks on result:
other: Lowest value of two independent determinations (1 and 4)

Results:

Pre-test:

The flash point of the test item was estimated at 70.0°C during the pre-test.

First determination:

The flash point of the test item was estimated at 70.0°C during the first determination.

An automatic correction was applied to the obtained result because the ambient pressure was not 101.3 kPa but 98.2 kPa.

With this correction, the flash point value is 71.0°C at 101.3 kPa.

Second determination:

The flash point was detected at 72.0°C and the same automatic correction was applied because the ambient pressure was still 98.2 kPa.

With this correction, the flash point value is 73°C at 101.3 kPa.

As the two first determinations do not meet the validation criteria (no more than 1°C of difference), a new determination is perfomed.

Third determination:

The flash point was detected at 65.0°C and the same automatic correction was applied because the ambient pressure was still 98.2 kPa.

With this correction, the flash point value is 66.0°C at 101.3 kPa.

However it was revealed that a wrong cleaning of the cup was performed at the end of the second determination and affects the result of the third determination. For this reason, resultts of this determination are not considered for this study.

Fourth determination:

The flash point was detected at 69.0°C and the same automatic correction was applied because the ambient pressure was still 98.2 kPa.

With this correction, the flash point value is 70.0°C at 101.3 kPa.

Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The corrected flash point of test item (E,Z)-2,6-DIMETHYLOCTA-2,4,6-TRIENE was determined to be 70.0°C at 101.3 kPa (lowest value of two independent determinations). Therefore, (E,Z)-2,6-DIMETHYLOCTA-2,4,6-TRIENE is not classified as flammable according to CLP regulation (EC) No 1272/2008. No signal word or hazard statement is required. The substance is classified as flammable category 4 (H227) according to GHS Regulation.
Executive summary:

A study was performed to determine the flash point of test item (E,Z)-2,6-DIMETHYLOCTA-2,4,6-TRIENE. The method followed was designed to be compliant with the Method A.9 of Commission Regulation No. 440/2008, ''Flash Point''.

The flash point of the test item is determined with a closed cup tester, by an equilibrium method called "Small Scale", (commonly known as Setaflash).

The substance is placed into a test cup and heated using a temperature gradient program. Ignition trials are carried out in order to ascertain whether or not the sample flashes at the temperature tested.

A pre-test followed by four determinations were conducted. For the pre-test, a flash point of 70.0°C was observed. This data was used to select the range of temperatures for the following determinations.

Determinations 1 and 4 respectively gave a corrected flash point of 71.0°C and 70.0°C at 101.3kPa.

Moreover the flash point of the reference substances glycerol and CRM respects the checking cards limits.

The corrected flash point of the test item was determined to be 70.0°C at 101.3 kPa (lowest value of two independent determinations). Therefore, (E,Z)-2,6-DIMETHYLOCTA-2,4,6-TRIENE is not classified as flammable according to CLP regulation (EC) No 1272/2008. No signal word or hazard statement is required. The substance is classified as flammable category 4 (H227) according to GHS Regulation.

Description of key information

The flash point was determined with a closed cup tester by Setaflash method.

The flash point of (E,Z)-2,6-DIMETHYLOCTA-2,4,6-TRIENE is 70°C.

The substance is not classified as flammable according to Regulation (EC) No 1272/2008 (CLP) criteria.

The substance is classified as flammable category 4 (H227) according to GHS Regulation.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
70 °C

Additional information

The flash point of neryl acetate was determined in a study performed according to EU method A.9.

As the results were obtained under GLP without deviation, they were considered as valid and reliable without restriction and used as key value.