Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013-01-24 to 2013-02-05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP and Guideline compliant study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13736:1997 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
1997
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
lsopropylmagnesium chloride
IUPAC Name:
lsopropylmagnesium chloride
Test material form:
other: lsopropylmagnesium chloride ca. 20% in THF

Results and discussion

Flash point
Flash point:
-27 °C
Atm. press.:
1 013.3 hPa

Applicant's summary and conclusion

Conclusions:
The flash point of the test item is -27.0 °C under atmospheric conditions (1013.3 hPa).
Executive summary:

The solvent of the test item is THF. As the literature gave a flash point below 0 °C for pure THF, the test item was submitted to the flash point measurement according to Abel and a preliminary test was not necessary. The final flash point rounded down with an accuracy of 0.5 °C from the mean value of both main tests is -27.0 °C.