Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1996-06 to 1996-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report date:
1996

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
421-300-1
EC Name:
-
Cas Number:
138564-59-7
Molecular formula:
C12H9N3O2S
IUPAC Name:
5-methyl-2-[(2-nitrophenyl)amino]thiophene-3-carbonitrile
Test material form:
solid: particulate/powder
Details on test material:
97.7%
Item code QA405K
Lilly lot no: 356MO1
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor and 356M01

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Ambient, dark

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance was found to be not explosive according to GHS criteria.
Executive summary: