Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-02-07 to 2018-03-29
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test L.2 (Sustained combustibility test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Abel-Pensky apparatus
Key result
Flash point:
151.5 °C
Atm. press.:
1 013.25 hPa

Preliminary Test

The test result of the preliminary test with the search program is presented in the following table. An ignition is indicated by + and no ignition by -.

Preliminary test

Amount of test item / g

Temperature / °C

Ignition (+/-)

Air pressure / hPa

Remark

2.0

≤100

-

1000.8

--

4.0

180

(+)

--

In the preliminary test the ignition flame was enlarged at a temperature of approx. 150 °C. At 180 °C the whole sample burned in the apparatus, which could be observed visually. The apparatus detected no ignition. Thus the main test was performed, starting at 170 °C.

 

Main test

The test results of the main test are presented in the following table. An ignition is indicated by + and no ignition by -.

 

Amount of test item / g

Temperature / °C

Ignition (+/-)

Air pressure / hPa

Remark

2.0

170.0

+

1018.3

--

1.9

165.0

+

1.9

160.0

+

1.9

155.0

+

1.9

150.0

-

1.9

151.0

-

1.9

152.0

+

2.0

151.5

-

1.9

151.5

-

2.0

151.5

-

In the main test the lowest temperature where an ignition was observed was 152.0 °C.

The measured flash point is corrected to the ambient pressure to be 151.9 °C.

The resulting corrected flash point rounded down to the nearest multiple of 0.5 °C is 151.5 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
The resulting corrected flash point rounded down to the nearest multiple of 0.5 °C was determined to be 151.5 °C.
Executive summary:

A study was conducted according to Regulation (EC) No 440/2008 method A.9, OPPTS 830.6315 and ISO 3679:2004 to determine flash point of the test item using a closed cup method. The start temperature for the main test (170 °C) was chosen based on he preliminary test. Therefore 2 mL of the test item are filled in the cup and heated to the estimated temperature. Then the substance was maintained for at least 1 minute at this temperature. The flame was dipped in the cup and it was checked if ignition occurred. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be at 151.9 °C (corrected to the ambient pressure). Thus, the flash point of the test item was determined to be 151.5 °C (corrected and rounded down to the nearest multiple of 0.5 °C) at 1013.25 hPa.

Description of key information

The resulting corrected flash point rounded down to the nearest multiple of 0.5 °C was determined to be 151.5 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
151.5 °C

Additional information

A study was conducted according to Regulation (EC) No 440/2008 method A.9, OPPTS 830.6315 and ISO 3679:2004 to determine flash point of the test item using a closed cup method. The start temperature for the main test (170 °C) was chosen based on he preliminary test. Therefore 2 mL of the test item are filled in the cup and heated to the estimated temperature. Then the substance was maintained for at least 1 minute at this temperature. The flame was dipped in the cup and it was checked if ignition occurred. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be at 151.9 °C (corrected to the ambient pressure). Thus, the flash point of the test item was determined to be 151.5 °C (corrected and rounded down to the nearest multiple of 0.5 °C) at 1013.25 hPa.