Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 September 2017 - 25 September 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Key result
Percentile:
other: D[4,3] – Mass Moment Mean – De Brouckere Mean Diameter
Mean:
70.32 µm
St. dev.:
1.268
Key result
Percentile:
D10
Mean:
9.492 µm
Remarks on result:
other: St. dev. not specified.
Key result
Percentile:
D50
Mean:
55.35 µm
Remarks on result:
other: St. dev. not specified.
Key result
Percentile:
D90
Mean:
12.08 µm
Remarks on result:
other: St. dev. not specified.
No.:
#1
Size:
< 2 µm
Distribution:
3.94 %
No.:
#2
Size:
< 200 µm
Distribution:
97.4 %

Table 1. Results of particle size distribution

Size

Test number and fraction size [%]

1

2

3

4

5

Average

less than 2 µm

3.75

3.92

3.95

3.98

4.08

3.94

less than 200 µm

97.3

97.4

97.2

97.3

97.6

97.4

[µm]

d10

9.986

9.606

9.501

9.37

8.996

9.492

d50

55.99

55.59

55.32

55.02

54.85

55.35

d90

120.7

120.5

120.7

119.8

118.7

120.08

*d4,3, [µm]

70.98

70.79

71.18

70.56

68.09

70.32

Average d43,[µm]

70.32

Standard deviation,[µm]

1.268

Relative Standard Deviation,[%]

1.80

Conclusions:
The mass moment mean of the tested material is determined to be 70.32 µm. The percentiles of particle size are: d10 = 9.492 µm, d50 = 55.35 µm, and d90 = 120.08 µm.
Executive summary:

The determination of particle size distribution was carried out in accordance with the International Standard ISO 13320-1 and following the Principles of GLP. It was performed passing a laser through a test substance suspension and measuring the light scattered at different angles by a multi-element detector. The mass moment mean (De Brouckere Mean Diameter) of the tested material is determined to be 70.32 µm and the percentiles of particle size are: d10= 9.492 µm, d50= 55.35 µm, and d90= 120.08 µm.

Description of key information

Key study: Test method according to according to International Standard ISO 13320-1. GLP study. The mass moment mean of the tested material is determined to be 70.32 µm. The percentiles of particle size are: d10 = 9.492 µm, d50 = 55.35 µm, and d90 = 120.08 µm.

Additional information

Key study: The determination of particle size distribution was carried out in accordance with the International StandardISO 13320-1and following the Principles of GLP. It was performed passing a laser through a test substance suspension and measuring the light scattered at different angles by a multi-element detector. The mass moment mean (De Brouckere Mean Diameter) of the tested material is determined to be 70.32 µm and the percentiles of particle size are: d10= 9.492 µm, d50= 55.35 µm, and d90= 120.08 µm.