Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) - Method B: Fibre Length and Diameter Distributions
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187 Particle Size Analysis by Laser Diffraction
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Dipotassium tetraoxomolybdate
EC Number:
236-599-2
EC Name:
Dipotassium tetraoxomolybdate
Cas Number:
13446-49-6
Molecular formula:
K2MoO4
IUPAC Name:
dipotassium tetraoxomolybdate
Test material form:
solid

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
37.1 µm
St. dev.:
0.19
Key result
Percentile:
D50
Mean:
151.12 µm
St. dev.:
3.44
Key result
Percentile:
D90
Mean:
535.3 µm
St. dev.:
54.21
Particle size distribution at different passagesopen allclose all
Size:
4 µm
Distribution:
0.09 %
Remarks on result:
other: Cumulative passing of specific particle sizes
Size:
10 µm
Distribution:
1.41 %
Remarks on result:
other: Cumulative passing of specific particle sizes
Size:
100 µm
Distribution:
37.8 %
Remarks on result:
other: Cumulative passing of specific particle sizes

Any other information on results incl. tables

Results

Two test series of 3 measurements each were performed with the test item.

Figure 1 and Figure 2 show the results of both test series. On the left y-axis the fraction distribution and on the right y-axis the cumulative distribution are shown.

Test series 1

D10

37.2 µm

Standard deviation: 0.80 µm

D50

154.6 µm (Median diameter)

Standard deviation: 4.13 µm

D90

589.5µm

Standard deviation: 36.87 µm

Test series2

D10

36.9 µm

Standard deviation: 0.62 µm

D50

147.7µm (Median diameter)

Standard deviation: 3.19 µm

D90

481.1µm

Standard deviation: 28.77 µm

Average

D10

37.1 µm

Standard deviation: 0.19 µm

D50

151.12 µm (Median diameter)

Standard deviation: 3.44 µm

D90

535.3 µm

Standard deviation: 54.21 µm

The percentages of the cumulative particle size distribution for specific particle sizes are shown in Table 1.

Table 1: Cumulative passing of specific particle sizes

Particle size /µm

Passing / %
Test Series 1

Passing / %
Test Series 2

Passing / %
Mean

2

0.00

0.00

0.00

4

0.09

0.08

0.09

10

1.46

1.36

1.41

20

3.69

3.65

3.67

100

34.23

35.37

34.80

200

59.91

62.19

61.05

250

68.14

70.88

69.51

500

87.12

90.74

88.93

1000

96.57

98.24

97.41

2000

100.00

100.00

100.00

Applicant's summary and conclusion