Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ISO 3104
GLP compliance:
yes
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Reference substance name:
Automatically generated during migration to IUCLID 6, no data available
IUPAC Name:
Automatically generated during migration to IUCLID 6, no data available
Test material form:
other: liquid
Details on test material:
- Molecular formula (if other than submission substance): Not applicable (UVCB substance)
- Molecular weight (if other than submission substance): Not applicable (UVCB substance)
- Smiles notation (if other than submission substance): Not applicable (UVCB substance)
- InChl (if other than submission substance): Not applicable (UVCB substance)
- Composition of test material, percentage of components: As described in section 1.2 excluding (Fe(O)(OH)).

Results and discussion

Viscosity
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
51.9
Remarks on result:
other: As the substance is a test material only, a single determination was made.

Applicant's summary and conclusion

Conclusions:
A viscosity of 51.9 mm2/s was determined for the test substance in a reliable study according to ISO 3104.