Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 3680 (Determination of flash/no flash - Rapid equilibrium closed cup method)
Version / remarks:
2005
Deviations:
not specified
GLP compliance:
no
Other quality assurance:
other: accredited institute according to UNI CEI EN 45001
Type of method:
equilibrium method closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
2-{[(4R,5R)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol; 2-{[(4R,5S)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol; 2-{[(4S,5R)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol; 2-{[(4S,5S)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol
EC Number:
700-535-6
Cas Number:
1190931-34-0
Molecular formula:
C6F6H6O5
IUPAC Name:
2-{[(4R,5R)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol; 2-{[(4R,5S)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol; 2-{[(4S,5R)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol; 2-{[(4S,5S)-2,2,4-trifluoro-5-(trifluoromethoxy)-1,3-dioxolan-4-yl]oxy}ethan-1-ol
Test material form:
liquid
Details on test material:
Test sample Name: Diox Alcohol
Purity: not specified

Results and discussion

Flash point
Key result
Flash point:
ca. 94 °C
Atm. press.:
ca. 1 020 mBar

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point was determined at 94°C at 1020 mbar.
Executive summary: