Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 500-290-3 | CAS number: 103758-99-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- migrated information: read-across based on grouping of substances (category approach)
- Adequacy of study:
- key study
- Study period:
- 28 November to 05 December 2012
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP study conducted according to relevant testing guidelines, with no significant deviations.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 013
- Report date:
- 2013
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
- Deviations:
- no
- GLP compliance:
- yes
Test material
- Reference substance name:
- Fatty acids, C18-unsatd., dimers, oligomeric reaction products with tall-oil fatty acids and triethylenetetramine
- EC Number:
- 500-191-5
- EC Name:
- Fatty acids, C18-unsatd., dimers, oligomeric reaction products with tall-oil fatty acids and triethylenetetramine
- Cas Number:
- 68082-29-1
- IUPAC Name:
- Fatty acids, C18-unsatd, dimers, polymers with tall-oil fatty acids and triethylenetetramine
- Reference substance name:
- TOFA_DimerFA_TETA_PAA
- IUPAC Name:
- TOFA_DimerFA_TETA_PAA
- Test material form:
- liquid: viscous
- Details on test material:
- The test material, TOFA_DimerFA_TETA_PAA, was a pale yellow viscous material, with batch number BB 001030 V1. The test material was stored in a sealed container at room temperature, in the dark. The analytical purity was 100%.
Constituent 1
Constituent 2
Test animals / tissue source
- Species:
- other: Not applicable - in vitro study
- Strain:
- other: Not applicable - in vitro study
- Details on test animals or tissues and environmental conditions:
- Not applicable - in vitro study
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- other: negative and positive control substances were included
- Amount / concentration applied:
- 750 µL. One cornea was treated with 1 mL of the test material, but this was not considered to have affected the integrity or outcome of the study.
- Duration of treatment / exposure:
- 10 minutes
- Observation period (in vivo):
- Not applicable
- Number of animals or in vitro replicates:
- The test material was applied to a separate group of three corneas.
- Details on study design:
- Bovine eyes were supplied by a local abbatoir. The eyes were removed after slaughter, completely immersed in Hanks’ Balanced Salt Solution (containing penicillin at 100 IU/mL and streptomycin at 100 µg/mL) in a suitably sized container and transported on the same day to the testing facility. On arrival the eyes were examined for defects including increased opacity, scratches and neovascularisation. Only corneas without such defects were used.
Upon arrival at the test facility, the corneas were excised from the eyes and loaded onto specifically designed holders. Both chambers of each holder were filled with pre-warmed Eagle’s Minimal Essential Medium (EMEM), ensuring that no bubbles were formed. The holders were incubated at 32°C ± 1°C for at least 1 hour. After the incubation, the media was removed from both the anterior and posterior chambers. Fresh media was added to the posterior chamber first and then the anterior chamber (this media replacement order ensured the cornea retained its natural curvature as much as possible). The opacity of each cornea was measured using an opacitometer. Any corneas found to have scratches or increased neovascularisation or an opacity of >7 opacity units when examined prior to treatment were discarded.
A volume of 750 µL of test material was applied to each of three corneas. The corneas were then incubated for 10 minutes at 32°C ± 1°C. After the incubation period, each cornea was washed with with media containing phenol red (as a pH indicator) until this indicator showed no pH effect occurring (and demonstrating that the test article had been removed successfully). The corneas were then washed in media without phenol red and the opacities measured. The corneas were incubated (horizontally) for 2 hours ± 10 minutes after which, the opacities were measured and then the anterior chamber emptied. For the permeability endpoint, 1 mL of sodium fluorescein (4 mg/mL solution) was added into the anterior chamber and the corneas were incubated in the vertical position for 1.5 hours ± 5 minutes. Following this period, the media in the posterior chamber was removed and held in a labelled tube. Three 350 μL aliquots of this media (per cornea) were analysed for optical density at 490 nanometres (OD490) using a spectrophotometer.
Positive (dimethyl formamide) and negative (0.9% sodium chloride solution) controls were handled in an identical manner.
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- 10 minutes
- Value:
- 31.9
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
Any other information on results incl. tables
Table 1. Corneal opacity
Group |
Cornea number |
Initial opacity |
Post incubation opacity |
Change in opacity |
Mean change in opacity |
Corrected opacity |
Mean corrected opacity |
Test material |
3 |
2 |
51 |
49 |
N/A |
48.3 |
30.3 |
10 |
2 |
21 |
19 |
18.3 |
|||
32 |
6 |
31 |
25 |
24.3 |
|||
Negative Control |
15 |
4 |
4 |
0 |
4 |
-0.7 |
0.0 |
4 |
4 |
5 |
1 |
0.3 |
|||
37 |
4 |
5 |
1 |
0.3 |
|||
Positive Control |
17 |
4 |
63 |
59 |
N/A |
58.3 |
50.7 |
23 |
3 |
52 |
49 |
48.3 |
|||
30 |
6 |
52 |
46 |
45.3 |
Table 2. Corneal permeability
Group |
Cornea number |
Mean blank OD490 |
OD490 |
Corrected OD490 |
Mean Corrected OD490 |
Final Corrected OD490 |
Mean group Corrected OD490 |
Test material |
3 |
|
0.208 |
0.202 |
N/A |
0.098 |
0.105 |
10 |
|
0.065 |
0.059 |
-0.045 |
|||
32 |
|
0.372 |
0.366 |
0.262 |
|||
Negative Control |
15 |
0.06 |
0.058 |
0.052 |
0.006 |
-0.052 |
0.000 |
4 |
0.150 |
0.143 |
0.040 |
||||
37 |
0.122 |
0.116 |
0.012 |
||||
Positive Control |
47 |
|
0.356 |
0.350 |
N/A |
0.246 |
0.373 |
23 |
|
0.670 |
0.663 |
0.560 |
|||
30 |
|
0.423 |
0.417 |
0.314 |
Applicant's summary and conclusion
- Interpretation of results:
- not classified
- Remarks:
- Migrated information Criteria used for interpretation of results: EU
- Conclusions:
- The calculated IVIS score was 31.90, this is below the trigger value of 55.1 therefore the test material is not considered to be corrosive or severely irritating to the eye.
- Executive summary:
The potential for TOFA_DimerFA_TETA_PAA to cause corrosion or severe irritation was evaluated in excised bovine corneas using the bovine corneal opacity and permeability (BCOP) assay, according to OECD Test Guideline 437 and GLP.
A volume of 750 µL test material was applied to three separate corneas, followed by a 10 minute incubation period at 32°C ± 1°C. Following incubation each cornea was washed with media containing phenol red, followed by media without phenol red. The opacities were then measured and the anterior chamber was emptied. To evaluate permeability, sodium fluorescein solution was added into the anterior chamber and the corneas were incubated in the vertical position for 1.5 hours ± 5 minutes. Following incubation the media in the posterior chamber was removed and three 350 µL aliquots of the media (per cornea) were analysed for optical density at 490 nm (OD490). The negative control was 0.9% sodium chloride solution, and the positive control was dimethyl formamide.
The opacity and permeability measurements were used to calculate an In Vitro Irritancy Score (IVIS). The calculated IVIS for the test material was 31.90, this is below the trigger value of 55.1 therefore the test material is not considered to be corrosive or severely irritating to the eye.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.