Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10.09.2011 - 17.09.2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Data is from study report.
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
Measurement of relative amounts of particles present, sorted according to size
GLP compliance:
no
Type of method:
sieving
Type of distribution:
counted distribution
Specific details on test material used for the study:
- Name of test material : Potassium iodide
- Molecular formula : KI
- Molecular weight : 165.998g/mol
- Smiles notation : [K+].[I-]
- InChl : 1S/HI.K/h1H;/q;+1/p-1
- Substance type : Organic
- Physical state : Solid
Key result
Percentile:
D50
Mean:
> 225 - < 500 µm
Remarks on result:
other: Mass median diameter
No.:
#1
Size:
> 500 µm
Distribution:
8.73 %
No.:
#2
Size:
> 225 - < 500 µm
Distribution:
91.27 %
Conclusions:
The particle size distribution (granulometry) of potassium iodide by the sieve analysis method was found to be in the range of 225 micrometer to >500 micrometer. Majority of the particles were found to be in the size >225 to <500µm (91.27%).
Executive summary:

The particle size distribution (granulometry) of potassium iodide by the sieve analysis method was found to be in the range of 225 micrometer to >500 micrometer. Majority of the particles were found to be in the size >225 to <500µm (91.27%).

Description of key information

The particle size distribution (granulometry) of potassium iodide by the sieve analysis method was found to be in the range of 225 micrometer to >500 micrometer. Majority of the particles were found to be in the size >225 to <500µm (91.27%).

Additional information

The particle size distribution (granulometry) of potassium iodide by the sieve analysis method was found to be in the range of 225 micrometer to >500 micrometer. Majority of the particles were found to be in the size >225 to <500µm (91.27%).