Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Test was performed according to the Method A.9., Flash-point, Council Regulation (EC) No.440/2008, Published in O.J. L 142, 2008. Concrete testing was performed by non-equilibrium method with Pensky-Martens apparatus according to standard ISO 2719.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
84 °C

Additional information

Test was performed according to the Method A.9., Flash-point, Council Regulation (EC) No.440/2008, Published in O.J. L 142, 2008

 

Concrete testing was performed by non-equilibrium method with Pensky-Martens apparatus according to standard ISO 2719.

 

Flash-point of test substance Solvent Yellow 124 is 84.0 °C.

Standard uncertainty of determination was estimated to 1 °C.*

 

* Standard uncertainty is equal to one standard deviation.