Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 26 July 2021 to 21 April 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
Remarks:
No incident, which could have affected the quality or the interpretation of the results obtained, was observed.
GLP compliance:
yes (incl. QA statement)
Remarks on result:
not determinable
Remarks:
The test was not performed due to the viscosity of the test item.

Results
A filling assay was done at ambient temperature with the test item in a 2-cm edge cube. The test item leaked through the cube.


The test was not performed due to the viscosity of the test item.

Conclusions:
The test was not performed due to the too low viscosity of the test item. An assay was done at ambient temperature and all the test item leaked through the 45 µm mesh. The cube was empty in less than one hour.
Executive summary:

RELATIVE SELF-IGNITION TEMPERATURE OF SOLIDS
In compliance with Regulation (EC) No. 1907/2006, Council Regulation (EC) No. 440/2008 EC A.16. Method (2008)
The test was not performed due to the too low viscosity of the test item. An assay was done at ambient temperature and all the test item leaked through the 45 µm mesh. The cube was empty in less than one hour.

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Remarks:
No incident, which could have affected the quality or the interpretation of the results obtained, was observed.
GLP compliance:
yes (incl. QA statement)
Remarks on result:
not determinable
Remarks:
The test was not performed due to the too high viscosity of the test item for the test.

Results
A sampling assay was done at ambient temperature with a micropipette and it was impossible to sample the test item.
The test was not performed due to the too high viscosity of the test item for the test.

Conclusions:
The test was not performed due to the too high viscosity of the test item for the test.
Executive summary:

AUTO-IGNITION TEMPERATURE OF LIQUIDS
In compliance with Regulation (EC) No. 1907/2006, Council Regulation (EC) No. 440/2008 and EC A.15. method (2008) and NF T 20-037 (1985)
The test was not performed due to the too high viscosity of the test item for the test.

Description of key information

Due to the too high viscosity of the test item, the test of relative self-ignition temperature of liquid was not performed.


A test of relative self-ignition temperature of solid was attempted but the test was not performed due to the too low viscosity of the test item. An assay was done at ambient temperature and all the test item leaked through the 45 µm mesh. The cube was empty in less than one hour.

Key value for chemical safety assessment

Additional information