Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study initiation date: 1st November 2005, Study completion date: 27th March 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes (incl. QA statement)
Remarks:
from MHRA (UK GLP Monitoring authority)
Type of method:
HPLC estimation method
Media:
soil

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
482-140-6
EC Name:
-
Cas Number:
13641-96-8
Molecular formula:
Hill formula: C6 H7 N O3 CAS formula: C6 H7 N O3
IUPAC Name:
2-isocyanatoethyl prop-2-enoate

Study design

HPLC method

Details on study design: HPLC method:
EQUIPMENT
- Apparatus: Hewlett Packard 1050 Series Liquid Chromatograph
- Type, material and dimension of analytical (guard) column: Hypersil CPS (25 cm x 4.6 mm internal diameter)
- Detection system: UV at 210 nm

MOBILE PHASES
- Type: Acetonitrile:water (55:45 v/v)
- Flow rate: 1.0 ml/min
- Injection volume: 20 Dl

REFERENCE SUBSTANCES
- Identity:
Internal deadtime standard (I.D.S.)
Acetanilide
Nitrobenzene
Naphthalene
2-Methylnaphthalene
Anthracene
DDT

Results and discussion

Adsorption coefficient
Type:
Koc
Value:
2
Temp.:
30 °C

Any other information on results incl. tables

HPLC determination of log10Koc for AOI:

Sample

Component

tr(minutes)

k

log10k

log10Koc

Standard Run A

(t0= 2.948 minutes)

Acetanilide

3.394

0.151

-0.820

1.3

Nitrobenzene

4.023

0.365

-0.438

2.4

Naphthalene

4.587

0.556

-0.255

2.8

2-Methylnaphthalene

4.824

0.636

-0.196

3.9

Anthracene

5.307

0.800

-0.097

4.4

DDT

7.539

1.557

0.192

5.6

Sample A (t0= 2.952 minutes)

AOI

3.732

0.264

-0.578

2.0

Sample B (t0= 2.951 minutes)

AOI

3.729

0.264

-0.579

2.0

Standard Run B

(t0= 2.949 minutes)

Acetanilide

3.393

0.151

-0.822

1.3

Nitrobenzene

4.017

0.362

-0.441

2.4

Naphthalene

4.578

0.552

-0.258

2.8

2-Methylnaphthalene

4.813

0.632

-0.199

3.9

Anthracene

5.293

0.795

-0.100

4.4

DDT

7.509

1.546

0.189

5.6

A log10Koc value for AOI of 2.0 was thus obtained. Due to the known rapid hydrolysis of the test substance, the test samples were injected in acetonitrile rather than aqueous mobile phase to minimise degradation. The AOI peak at 3.7 minutes was noted to decrease in size, with coincident increase in size of the earlier eluting degradate peaks between 3.0 and 3.4, when a solution was prepared and analysed in mobile phase.

CONCLUSION

AOI was found to have log10Koc value of 2.0.

Applicant's summary and conclusion