Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Feb 26 - Mar 28, 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
Version / remarks:
July 26, 2013
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: Council Regulation (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006. B.40.bis. In vitro skin corrosion: human skin model test
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: bulk

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Cell source:
foreskin from a single donor
Justification for test system used:
standard model
Vehicle:
unchanged (no vehicle)
Remarks:
No vehicle used in this study; The test item was applied neat to the tissues.
Details on test system:
CELL CULTURE
- Supplier: EpiSkin/SkinEthic Laboratories, Lyon, France)
- Source: human keratinocytes cultured on a polycarbonate filter in conditions which permit their terminal differentiation
- Format: 24 well plate
- Batch: 19-RHE032
- Expires: March 11, 2019

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment: room temperature
- Temperature of post-treatment incubation: 37°C

REMOVAL OF THE TEST MATERIAL AND CONTROL
At the end of the exposure periods, the test item, positive and negative control was removed immediately by gently rinsing with a minimum volume of 20 mL DPBS using a pipette. Excess DPBS was removed by gently shaking the tissue inserts and blotting the bottom of the tissue inserts with blotting paper.

Control samples:
yes, concurrent negative control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 20 mg ± 3 mg of solid test material
- Concentration (if solution): n/a

VEHICLE
- Amount(s) applied (volume or weight with unit): n/a
- Concentration (if solution): n/a
- Lot/batch no. (if required): n/a
- Purity: n/a

NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 40 µL ± 3 µl (deionised water )
- Concentration (if solution): n/a

POSITIVE CONTROL
- Amount(s) applied (volume or weight): 40 µL ± 3 µl
- Concentration (if solution): A dodecyl sulfate sodium salt solution dissolved deionised water pure was used as positive control.
Duration of treatment / exposure:
42 min
Number of replicates:
3

Test system

Controls:
yes, concurrent negative control
Amount / concentration applied:
16 mg

Results and discussion

In vitro

Results
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
Mean relative viability in %
Value:
102.5
Vehicle controls validity:
not applicable
Remarks:
The test item was applied neat to the tissues
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
OTHER EFFECTS:
- Visible damage on test system: none
- Direct-MTT reduction: none
- Colour interference with MTT: none

ACCEPTANCE OF RESULTS:


-Acceptability of the Quality Control Data of the Skin Model with Reference to Historical Batch Data:
The OD values for the negative control shall be in the range of ≥ 0.8 and ≤ 3.0 as given in OECD Guideline 439

-Acceptability of the Positive and Negative Control based on Historical Data of the Testing Laboratory:
The negative control data meet the acceptance criteria if the mean OD value is higher or equal than a historically established boundary at 570 nm. The boundary is two standard deviations below the current historical mean (1.421). The positive control data meet the acceptance criteria if the mean viability value, expressed as % of the negative control, is lower than or equal to a historically established boundary. The boundary is three standard deviations above the current historical mean (2.79%).



-Test Substance Data Acceptance Criteria:
The standard deviation between the three tissues replicates treated with the test item was 0.76% and, thus, ≤18%.


The study met all acceptance criteria.





Any other information on results incl. tables

 Group Time / [min]  Mean OD  Mean Relative viability / [%]
 Negative Control 42 1.668 100.0

 Positive Control

42

0.022

1.3

 Test Material 42 1.710 102.5

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Remarks:
Non-corrosive
Conclusions:
This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439. Under the conditions of the present study, the test item is not considered to be irritant to skin.
Executive summary:

This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439.Under the conditions of the present study, the test item is not considered to be irritant to skin.