Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 Mar 2020 - 23 Apr 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
CIPAC MT 75 (Determination of pH Values)
Version / remarks:
Volume J MT 75.3; 2000
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 122 (Determination of pH, Acidity and Alkalinity)
Version / remarks:
26 July 2013
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7000 (pH)
Version / remarks:
August 1996
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-ethylhexyl 2-([1,1'-biphenyl]-4-ylcarbonyl)benzoate
EC Number:
278-051-5
EC Name:
2-ethylhexyl 2-([1,1'-biphenyl]-4-ylcarbonyl)benzoate
Cas Number:
75005-95-7
Molecular formula:
C28H30O3
IUPAC Name:
2-ethylhexyl 2-{[1,1'-biphenyl]-4-carbonyl}benzoate
Test material form:
liquid
Details on test material:
Purity/Composition: 96.27%
Storage Conditions: At room temperature
Test Facility test item number: 210244/A
Test item handling: No specific handling conditions required
CAS number: 75005-95-7
EC Number: 278-051-5
Substance Name: 2-ethylhexyl 2-([1,1'-biphenyl]-4-ylcarbonyl)benzoate
Specific details on test material used for the study:
Physical Description: Colourless to pale yellow liquid (determined by Charles River Den Bosch)
Purity/Composition: 96.27%
Storage Conditions: At room temperature
Purity/Composition correction factor: No correction factor required
Test item handling: No specific handling conditions required
Chemical name: 2-Ethylhexyl 2-([1,1'-biphenyl]-4-ylcarbonyl)benzoate
CAS number: 75005-95-7
EC Number: 278-051-5
Molecular formula: C28H30O3
Molecular weight: 414.22

Reagents

Reagent:
other: See below

Titration of acidity and alkalinity

Details on titrant used:
Chemicals and Reagents
Text Table 9
Chemicals and Reagents
Chemical / Reagent Supplier
Double distilled water Waldeck, Münster-Roxel, Germany
Potassium hydrogen phthalate (C8H5KO4) Merck, Darmstadt, Germany
Di-sodium tetraborate decahydrate (Na2B4O7.10H2O) Sigma-Aldrich, Steinheim, Germany
0.05M buffer solution pH 4.00 ± 0.02 5.1056 g potassium hydrogen phthalate dried for 2 hours at 105°C, dissolved in double distilled water and made up to 500 mL
0.05M buffer solution pH 9.22 ± 0.02 9.5353 g di-sodium tetraborate decahydrate dissolved in double distilled water and made up to 500 mL
All chemicals and reagents were of analytical grade, unless specified otherwise.

Performance of the Study
The pH of two 1% (w/v) mixtures of the test item in double distilled water was measured using a 906 Titrando (Metrohm, Herisau, Switzerland) and a combined glass electrode (glass glass electrode and reference electrode, Metrohm).
The pH meter was calibrated using a 0.05 M potassium hydrogen phthalate buffer solution (pH 4.00) and a 0.05 M di-sodium tetraborate buffer solution (pH 9.22 at 20°C). At the start and at the end of the measurements, pH of these buffer solutions was measured to ensure proper performance of the pH meter.
For the preparation of the 1% (w/v) mixtures, accurately weighed amounts of 1.0069 g and 1.0015 g of the test item were transferred into a 100 mL measuring cylinder, containing about 50 mL double distilled water. The volume was made up to 100 mL with water, the cylinder was stoppered and the dispersion was shaken vigorously by hand until completely mixed or dispersed. After it was left to stand for 1 minute, the combined glass electrode was immersed into the liquid and the pH was measured without stirring. The pH value was recorded after 1 and 2 minutes. Because the pH value changed more than 0.1 unit during this equilibration time, the pH was also recorded 10 minutes after immersion of the electrode.
The test was performed at 21.5 ± 0.4°C.

Results and discussion

pH value
pH value:
5.8
Temp.:
21.5 °C
Concentration:
1 other: % w/v

Any other information on results incl. tables

The results of the test on the determination of the pH of the test item are given in Table 8.

The 1% (w/v) mixtures of the test item in double distilled water were white turbid suspensions with drops of test item throughout the measuring cylinder.

The pH of the 1% (w/v) aqueous mixtures was 5.8.

Table 8   pH of the Test Item

  pH
1% (w/v) mixture
  5.616
  5.962
Mean 5.8

Applicant's summary and conclusion

Conclusions:
the pH of the substance was determined to be 5.8 under the conditions of the test.
Executive summary:

Under GLP conditions, the pH of the substance was determined to be 5.8 under the conditions of the test according to guidelines CIPAC MT 75.3, OECD 122 & OPPTS 830.7000.