Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
< 2 min
Interpretation of results:
not classified based on GHS criteria
Conclusions:
It can be ascertained that the sample is not a highly flammable solid based on the results of the preliminary screening test.
Executive summary:

The test showed that the sample could be ignited within 2 min; after removal of ignition, the sample didn't propagate combustion either by burning with flame or smoldering along 200 mm of the train within 4 min.

Conclusion: the sample is not a highly flammable solid.

Description of key information

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification