Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019-03-28 - 2019-03-28
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Version / remarks:
OECD Guideline 110 (1981): Particle size distribution
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
ISO 13320 (2009): Particle size analysis - Laser diffraction methods
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Percentile:
D10
Mean:
222 µm
St. dev.:
9.28
Key result
Percentile:
D50
Mean:
502 µm
St. dev.:
1.99
Percentile:
D90
Mean:
907 µm
St. dev.:
4.18
Conclusions:
The study was conducted under GLP according to OECD TG 110 and ISO 13320 without deviations and therefore reliability of Klimisch 1 has been assigned. Based on the obtained results the test item Magnesium perchlorate has a median particle size of D50 = 502 µm.
Executive summary:

The test item Magnesium perchlorate has a median particle size of D50 = 502 µm, which was determined by laser diffraction measurement according to OECD Test Guideline 110 (1981) and ISO 13320 (2009).

Description of key information

D50= 502 µm (OECD 110 and ISO 13320, laser diffraction measurement, GLP)

Additional information