Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: OECD Guidelines for Testing of Chemicals, Section 1 – Physical-Chemical Properties No: 113 “Screening Test for Thermal Stability and Stability in Air ”
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Other quality assurance:
other: Not specified
Type of method:
other: Differential Thermal Analysis (DTA) / Differential Scanning Calorimetry (DSC)
Key result
Atm. press.:
other: No pressure reported
Decomposition:
yes
Decomp. temp.:
>= 310 °C
Remarks on result:
not determinable
Remarks:
No boiling point could be determined

RESULTS:

  • From –60 to -40 °C an endothermic effect is visible which could indicate a glass transition
  • In the range of approx. 310 and approx. 430 °C an endothermic effect could be detected which could indicate decomposition of the test item
  • The decomposition of the test item is indicated by the brownish-blackish residue in the crucible after finalization of the test
  • Since no endothermic phases indicating melting could be detected, no further investigations were carried out
Conclusions:
No boiling point could be determined. Decomposition was determined between approx. 310 and 430 °C (Opala, 2018).
Executive summary:

The thermal stability and decomposition point by Differential Thermal Analysis (DTA)/Differential Scanning Calorimetry (DSC) was determined according OECD 102/OECD 113. No boiling point could be determined. From -60 to -40 °C an endothermic effect is visible which could indicate a glass transition. In the range of approx. 310 and approx. 430 °C an endothermic effect could be detected which could indicate decomposition of the substance.

Description of key information

No boiling point could be determined. Decomposition was determined between approx. 310 and 430 °C (Opala, 2018).

Key value for chemical safety assessment

Additional information

In the range of approx. 310 °C and approx. 430 °C an endothermic effect could be detected which could indicate decomposition of the substance.