Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
hydrolysis
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
This report represents data generated in accordance with the following Good Laboratory Practice Standards. OECD ENV/MC/CHEM(98)17, Paris, January 26, 1998. All phases of this study were conducted according to the above standards. However, nonstandard protocols were utilized due to the rapid hydrolysis of the test substance.

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2002
Report date:
2002
Reference Type:
publication
Title:
“Micellar effects upon acid catalyzed hydrolysis of Triphenyl phosphite.”
Author:
Al-Lohedan, Hamad A.
Year:
1991
Bibliographic source:
Phosphorous, Sulfur, Silicon Relat. Elem: 63 (3-4), 261-71. 1991.

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 111 (Hydrolysis as a Function of pH)
Deviations:
yes
Remarks:
Study plan deviated from OECD 111 because TPPi must be sufficiently soluble in test buffers to be detected by the analytical method.
Principles of method if other than guideline:
Method: HPLC
Test type: Hydrolytic stability
The HPLC method used in these studies was based on published reports (Baylocq et al, 1986; Stevenson et al, 1999; Stevenson, 1997; Munteanu et al 1985)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Triphenyl phosphite
EC Number:
202-908-4
EC Name:
Triphenyl phosphite
Cas Number:
101-02-0
Molecular formula:
C18H15O3P
IUPAC Name:
triphenyl phosphite
Radiolabelling:
not specified

Study design

Analytical monitoring:
yes
Positive controls:
no
Negative controls:
no

Results and discussion

Transformation products:
not specified
Identity of transformation products
No.:
#1
Reference
Reference substance name:
Unnamed
IUPAC name:
phenol
Inventory number:
InventoryMultipleMappingImpl [inventoryEntryValue=EC 203-632-7]
CAS number:
108-95-2
Identity:
Phenol
Molecular formula:
C6H6O
Molecular weight:
94.111
SMILES notation:
Oc1ccccc1
InChl:
InChI=1/C6H6O/c7-6-4-2-1-3-5-6/h1-5,7H
Dissipation DT50 of parent compoundopen allclose all
pH:
7
Temp.:
22 °C
DT50:
0.5 h
Type:
(pseudo-)first order (= half-life)
pH:
9
Temp.:
22 °C
DT50:
< 14 h
Type:
(pseudo-)first order (= half-life)
pH:
7
Temp.:
25
Hydrolysis rate constant:
0 s-1
DT50:
1.1 h
Type:
(pseudo-)first order (= half-life)

Any other information on results incl. tables

The results of experiments on aqueous/cosolvent TPPi solutions indicated that the half-lives of TPPi in deionized water (initially at pH 6-7) and pH9 buffer were approximately 0.5 hour and less than 14 hours respectively at 22 °C.

Aqueous Solvent

Cosolvent

Temp (°C)

Rate Constant

Half-

life (h)9

Source

Aq. HCl;

pH 1.3

(10)

25

1.8E-4 s-1

1.1

Al-Lohedanet al., (1991)

Deionized H2O; initial pH 6-7

Methanol (50%)

22

na11

~ 0.5

BCRI # 252 1518

pH 9 buffer

Acetonitrile (50%)

22

na

< 14

BCRI # 172 1403

9 this is the estimated half-life in the absence of cosolvent

10half-life extrapolated to pure water from results on ethanol/water mixtures

11not available from the data

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The results of experiments on aqueous/cosolvent TPPi solutions indicated that the half-lives of TPPi in deionized water (initially at pH 6-7) and pH 9 buffer were approximately 0.5 h and less than 14 h respectively at 22 °C. Due to these relatively short half-lives, a rapid method is required for the analysis of TPPi in aqueous solutions. However, the low water solubility of TPPi precludes such “direct injection” methods. This was shown by the injection of near saturated TPPi solutions in 1% CH3CH/buffers which showed insufficient HPLC responses. Therefore, an extraction method would be required for the analysis of TPPi in aqueous solutions, which is more time consuming and would likely produce erroneous results due to the relatively rapid hydrolysis of TPPi during the extraction procedure.

It follows that performance of the OECD hydrolysis test was considered not to be technically feasible under normal laboratory conditions. Regarding the hydrolytic pathway of TPPi, literature and experimental evidence indicates that TPPi hydrolyzes essentially completely to phenol and phosphorous acid, with little or no accumulation of the possible di and mono ester hydrolysis products.
Executive summary:

Based on the results of this experiment and previous work, the test substances appears to rapidly hydrolyze in water.

Al-Lohedan et al., (1991) reported a TPPi hydrolysis half-life of 1.1 h in water at pH 1.3 and 25 °C by extrapolation of results on TPPi solutions in ethanol/water. The results of BCRI experiments on aqueous/cosolvent TPPi solutions indicated that the half-lives of TPPi in deionized water (initially at pH 6 - 7) and pH 9 buffer were approximately 0.5 h and less than 14 h respectively, at 22 °C.

Regarding the hydrolytic pathway of TPPi, literature and BCRI experimental evidence indicates that TPPi hydrolyzes essentially completely to phenol and phosphorous acid, with little or no accumulation of the possible di- and mono-ester hydrolysis products.