Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Chemical structure
Reference substance name:
D-ribose
EC Number:
200-059-4
EC Name:
D-ribose
Cas Number:
50-69-1
Molecular formula:
C5H10O5
IUPAC Name:
D-ribose
Test material form:
solid: particulate/powder
Details on test material:
Dry powder, white to slightly yellow
Specific details on test material used for the study:
Appearance: White to slightly yellow powder
Batch: Q0926501
Purity/Composition: 99.3%
Test item storage: At room temperature protected from light
Stable under storage conditions until: 30 November 2019 (expiry date)

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 1.59 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

The individual measurements were obtained with an accuracy of < 0.02 g.cm-3.

According to the guideline, the density of the test item is given as the mean value.

Applicant's summary and conclusion

Conclusions:
According to the OECD109 guideline, EC Guideline A.3. and EPA OPPTS 830.7300, a gas comparison stereopycnometer was used for the determination of the density and relative density of D-ribose.
The density of the test item at 20ºC was 1.59 g/cm3 (1.59 x 10^3 kg/m3).
The relative density was 1.59.