Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10/11/2018 – 10/18/2018
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
27 July 1995
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
30 May 2008
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Test material form:
solid: particulate/powder

Results and discussion

Melting / freezing point
Key result
Decomposition:
yes
Decomp. temp.:
ca. 205 °C

Applicant's summary and conclusion

Conclusions:
No melting point was determined prior to the exothermic decomposition of the test item, starting at around 205 °C.