Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Description of first aid measures

General information

In all cases of doubt, or when symptoms persist, seek medical advice. In case of unconsciousness give nothing by mouth, place in recovery position and seek medical advice.

In case of inhalation:

Remove casualty to fresh air and keep warm and at rest. In case of irregular breathing or respiratory arrest provide artificial respiration. In case of respiratory tract irritation, consult a physician.

Following skin contact

Take off immediately all contaminated clothing. After contact with skin, wash immediately with plenty of water and soap. Do not use solvents or thinners. In case of skin irritation, consult a physician.

After eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical advice immediately.

After ingestion

Rinse mouth immediately and drink plenty of water. Seek medical advice immediately. Keep victim calm. Do NOT induce

vomiting.

Most important symptoms and effects, both acute and delayed

In all cases of doubt, or when symptoms persist, seek medical advice.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media:

Alcohol resistant foam, carbon dioxide, Powder, spray mist, (water), Sand.

Extinguishing media which must not be used for safety reasons:

Strong water jet

Special hazards arising from the substance or mixture

Dense black smoke occurs during fire. Inhaling hazardous decomposing products can cause serious health damage.

Advice for firefighters

In case of fire: Wear self-contained breathing apparatus, Full protection suit. Cool closed containers that are near the source of the fire. Do not allow water used to extinguish fire to enter drains, ground or waterways

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Ventilate affected area. Do not breathe vapours. Special danger of slipping by leaking/spilling product. See protective measures in section "handling and storage and "exposure controls/personal protection"

Environmental precautions:

Do not allow to enter into surface water or drains. If the product contaminates lakes, rivers or sewages, inform competent authorities in accordance with local regulations.

Methods and material for containment and cleaning up:

Isolate leaked material using non-flammable absorption agent (e.g. sand, earth, vermiculit, diatomaceous earth) and collect it for disposal in appropriate containers in accordance with the local regulations. Clean using cleansing

agents. Do not use solvents.

Reference to other sections

Observe protective provisions in section "handling and storage and "exposure controls/personal protection"

Handling and storage

Precautions for safe handling

Advices on safe handling

Avoid contact with skin, eyes and clothes. When using do not eat, drink or smoke. Personal protection equipment: See section "Exposure controls/personal protection". Do not empty containers with pressure - no pressure vessel! Always keep in containers that correspond to the

material of the original container. Follow the legal protection and safety regulations.

Conditions for safe storage, including any incompatibilities

Packaging materials:

Incompatible materials: Iron.

Requirements for storage rooms and vessels:

Storage in accordance with the Ordinance on Industrial Safety and Health. Keep container tightly closed. Do not empty containers with pressure - no pressure vessel!; Smoking is forbidden. Access only for authorised persons. Store carefully closed containers upright to prevent any leaks.

Hints on joint storage:

Keep away from strongly acidic and alkaline materials as well as oxidizers.

Further information on storage conditions:

Take care of instructions on label. Store in a well-ventilated and dry room at temperatures between 5 °C and 30 °C. Protect from heat and direct sunlight. Keep container tightly closed. Remove all sources of ignition. Smoking is forbidden. Access only for authorised persons. Store carefully closed containers upright to prevent any leaks.

Specific end use(s)

Observe technical data sheet. Observe instructions for use

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 3265
Shipping information
Proper shipping name and description:
Corrosive liquid, acidic, organic, n.o.s. (Phytic acid) solution
Chemical name:
Esters of phosphoric acid with myo-Inositol, plant derived (UVCB)
Old IUPAC name for monoconstituent substance: (1R,2S,3r,4R,5S,6s)-1,2,3,4,5,6-Cyclohexanehexayl hexakis[dihydrogen (phosphate)]
Language:
English
Special provisions / remarks
Special provisions:
Tunnel Restriction Code: E (Passage forbidden through tunnels of category E.)

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 3265
Shipping information
Proper shipping name and description:
Corrosive liquid, acidic, organic, n.o.s. (Phytic acid) solution
Chemical name:
Esters of phosphoric acid with myo-Inositol, plant derived (UVCB)
Old IUPAC name for monoconstituent substance: (1R,2S,3r,4R,5S,6s)-1,2,3,4,5,6-Cyclohexanehexayl hexakis[dihydrogen (phosphate)]
Language:
English
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN 3265
Shipping information
Proper shipping name and description:
CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S. (Phytic acid) SOLUTION
Chemical name:
Esters of phosphoric acid with myo-Inositol, plant derived (UVCB)
Old IUPAC name for monoconstituent substance: (1R,2S,3r,4R,5S,6s)-1,2,3,4,5,6-Cyclohexanehexayl hexakis[dihydrogen (phosphate)]
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 3265
Shipping information
Proper shipping name and description:
Corrosive liquid, acidic, organic, n.o.s. (Phytic acid) solution
Chemical name:
Esters of phosphoric acid with myo-Inositol, plant derived (UVCB)
Old IUPAC name for monoconstituent substance: (1R,2S,3r,4R,5S,6s)-1,2,3,4,5,6-Cyclohexanehexayl hexakis[dihydrogen (phosphate)]
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters

Occupational exposure limit values:

not applicable

Exposure controls:

Provide good ventilation. This can be achieved with local or room suction. If this should not be sufficient to keep aerosol and solvent vapour concentration below the exposure limit values, a suitable respiratory protection must be used.

Occupational exposure controls

Respiratory protection

If concentration of solvents is beyond the occupational exposure limit values, approved and suitable respiratory protection must be used. Observe the wear time limits according GefStoffV in combination with the rules for using respiratory protection apparatus (BGR 190). Use only respiratory protection equipmentwith CE-symbol including four digit test number.

Hand protection

For prolonged or repeated handling the following glove material must be used: PVC (Polyvinyl chloride), NBR (Nitrile rubber), CR (polychloroprene, chloroprene rubber). Thickness of the glove material > 0,4 mm ; Breakthrough time (maximum wearing time) > 480 min.

Observe the instructions and details for use, storage, maintenance and replacement provided by the protective glove manufacturer. Penetration time of glove material depending on intensity and duration of exposure to skin. Recommended glove articles DIN EN 374. Barrier creams can help protecting exposed skin areas. In no case should they be used after contact.

Eye protection

Wear closely fitting protective glasses in case of splashes.

Protective clothing

Wear antistatic clothing of natural fibers (cotton) or heat resistant synthetic fibers.

Protective measures

After contact clean skin thoroughly with water and soap or use appropriate cleanser.

Environmental exposure controls

Do not allow to enter into surface water or drains. See also section "Handling and storgae". No additional measures necessary.

Stability and reactivity

Reactivity

Chemical stability

Stable when applying the recommended regulations for storage and handling.

Further information on correct storage: Refer to section "Handling and storage"

Possibility of hazardous reactions

Keep away from strong acids, strong bases and strong oxidizing agents to avoid exothermic reactions.

Conditions to avoid

Stable when applying the recommended regulations for storage and handling.

Further information on correct storage: Refer to section "Handling and storage".

Hazardous decomposition byproducts may form with exposure to high temperatures.

Incompatible materials

Iron.

Hazardous decomposition products

Hazardous decomposition byproducts may form with exposure to high temperatures, e.g.: carbon dioxide, carbon monoxide, smoke.

Disposal considerations

Waste treatment methods

Appropriate disposal / Product Recommendation

Do not allow to enter into surface water or drains. This material and its container must be disposed of in a safe way. Waste disposal according to directive 2008/98/EC, covering waste and dangerous waste.

List of proposed waste codes/waste designations in accordance with EEC:

Code: 070699: Wastes not otherwise specified

Packaging Recommendation

Non-contaminated packages may be recycled. Vessels not properly emptied are special waste