First-aid measures

Inhalation: Remove to fresh air.
Eyes: Flush eyes with adequate amounts of water for at least fifteen (15) minutes. Take care not to flush contaminated water into unaffected eye. Use tepid water if possible.
Skin: Remove clothes, flush skin with copious amounts of running water. If irritation develops after washing, get medical attention. Wash exposed areas, hands, face, etc. before going home, eating, and smoking.
Ingestion: If small amounts have been swallowed, rinse mouth out, drink plenty of water, and If larger amounts have been ingested, get medical attention. Induce vomiting only if directed by medical personnel.

Fire-fighting measures

Suitable Extinguishing Media: Any standard extinguishing medium, including water.
Unsuitable Extinguishing Media: NA
Special Exposure Hazards: This material will auto ignite at temperatures approximately 365°F (185°C).
Products of Combustion: Can produce nitrogen, nitrogen oxides, carbon monoxide, carbon dioxide, ammonia, methane, copper, metal oxides, and water.
Protection of Firefighters: Fight surrounding fire at a distance until material has burned.
Special Protective Equipment for Firefighters: NA

Accidental release measures

Personal Precautions: Use impervious gloves, safety goggles, dust mask, safety shoes, and flame treated clothing when cleaning spills.
Environmental Precautions: NA
Methods For Containment and Clean-up: Contain the material and clean up with non-sparking tools. Avoid spark, static electricity, and open flame. Avoid raising dust and ventilate area. Wash spill site with water after material pick-up is complete. Follow all current and applicable laws and regulations.

Handling and storage

Handling: Avoid spark, ESD, impact, friction and open flame.
Storage: Store away from high temperatures, open flame, static electricity, and other ignition sources. Store in transportainers, explosive cabinets or other approved storage facility.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure Limit Values
-Guanidine nitrate: NE (OSHA-PEL, ACGIH-TLV)
-Copper Diammine Dinitrate: NE (OSHA-PEL, ACGIH-TLV)
-Silica-Amorphous, fumed: 30 mg/m3 (OSHA-PEL), 2 mg/m3 (ACGIH-TLV)

Engineering Controls: Use approved engineering controls to minimize exposure to ESD. Use approved personal protective equipment as a short-term control until engineering controls are adequate.

Personal Protective Equipment
-Respiratory Protection: Adequately designed local exhaust systems are the first choice for employee protection. As a short-term fix, personal protective equipment, including appropriate respirators may be used until engineering controls are installed and verified as effective, by a qualified Industrial Hygienist or equivalent.
-Hand Protection: Protective gloves.
-Eye Protection: Safety goggles/glasses. Protect skin around the eyes.
-Skin Protection: Avoid skin contact with material.
-General Hygiene Responsibilities: Use good personal hygiene at all times.

Stability and reactivity

Reactivity: Unknown
Chemical Stability: May become unstable if heated.
Possibility of hazardous reactions: Unknown
Conditions To Avoid: Sparks, static electricity, open flame and hot temperatures
Incompatible Materials: Strong acids and bases
Hazardous Decomposition Products: Can produce nitrogen, nitrogen oxides, carbon monoxide, carbon dioxide, ammonia, copper and other metals, metal oxides, and amorphous silica.

Disposal considerations

See section Regulatory Information:
TSCA Chemical Inventory: The components of this product are listed on the Toxic Substance Control Act (TSCA) inventory.
CERCLA Reportable Quantity, 40 CFR 302: yes
EPCRA Section 302, Extremely Hazardous Substances: no
EPCRA Section 311/312, Hazard Category: yes
EPCRA Section 313, Toxic Chemicals: yes
RCRA INFORMATION: This product as described in this MSDS could meet the definition of a RCRA Reactive Hazardous (D003) under 40 CFR 261.23. Other regulations may apply. Please check federal, state or provincial and local regulations.