Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The substance is not considered as flammable solid, liquid or gas, flammable in contact with water, pyrophoric liquid or solid, and self-heating substance.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammable gases

The test item is a liquid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as flammable gas.

 

Flammable liquids

 A study was conducted according to Regulation (EC) No 440/2008 method A.9, to determine flash point of the test item using a closed cup method. In the preliminary test, no ignition was observed up to 100 °C. At 100 °C the ignition flame extinguished. Thus, the flash point of the test item was determined to be above 90 °C. Thus, the substance does not need to be classified as flammable liquid.

 

Flammable solids

The test item is a liquid at ambient conditions. This hazard class is only applicable for solids. Thus, the substance was not considered for classification as flammable solid.

 

Pyrophoric properties of liquids

In accordance with section 2.9.4 Annex I of Regulation (EC) No 1272/2008 and ECHA guidance on the application of CLP Criteria section 2.10.4.2 the classification procedure for pyrophoric liquids need not to be applied when experience in manufacturing or handling shows that the substance or mixture does not ignite spontaneously when coming into contact with air at normal temperatures. Based on the experience in handling and use the substance is not known to ignite spontaneously when coming into contact with air at normal temperatures. Thus, no study was conducted and the substance was not considered for classification as pyrophoric liquid.

 

Pyrophoric solids

The test item is a liquid at ambient conditions. This hazard class is only applicable for solids. Thus, the substance was not considered for classification as pyrophoric solid.

 

Substances which, in contact with water, emit flammable gases

In accordance with column 2 of REACH Annex VI and with Regulation (EC) No 1272/2008 Annex I section 2.12.4.1 the classification procedure for this hazard class need not be applied. Based on the experience in handling and use the substance does not react with water and in addition the test substance is not pyrophoric. Thus, no study was conducted and the substance was not considered for classification.

 

Self-heating substances and mixtures

In accordance with ECHA guidance on the Application of the CLP Criteria section 2.11.4.2 and ECHA guidance on IR/CSA chapter R.7a section R7.1.10.7 the test does not to be conducted as in general liquids are not classified as self-heating since the phenomena applies only to solids and the test method is not applicable to liquids according to ECHA guidance on the Application of the CLP Criteria section 2.11.4.2.

 

Flammable Aerosols

Section 2.4.2 of Guidance on the application on the CLP Criteria state as follows:

“Aerosols, this means aerosol dispensers, are any non-refillable receptacles made of metal, glass or plastics and containing a gas compressed, liquefied or dissolved under pressure, with or without a liquid, paste or powder, and fitted with a release device allowing the contents to be ejected as solid or liquid particles in suspension in a gas, as a foam, paste or powder or in a liquid state or in a gaseous state. Thus, as the substance does not meet the definition for aerosol, the test for aerosols was waived. Consequently the substance has not to be considered for classification for this hazard class.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No 1272/2008

In accordance with Annex I Section 2.2, Section 2.3, Section 2.6, Section 2.7, Section 2.9, Section 2.10, Section 2.11, Section 2.12 of Regulation (EC) No 1272/2008 and UN GHS Rev 7 (2017) the test item has not to be classified as flammable liquid, readily combustible solid in class 4 Division 4.1, self-heating substance in Class 4 Division 4.2, substances which in contact with water emit flammable gases in Class 4 Division 4.3, pyrophoric liquid, pyrophoric solid in class 4 Division 4.2, flammable gases in class 2 or as aerosol in class 2.