Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-02-06 to 2018-02-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
>= 90 °C
Atm. press.:
1 013.25 hPa

Preliminary Test

The result of the preliminary test with the search program is summarized in the following table. The result “ignition” is indicated by + and “no ignition” by -.

 

Preliminary test results

Amount of test item / g

Temperature / °C

Ignition (+/-)

Air pressure / hPa

68.42

up to 90

-

1007.6

68.68

up to 90

-

1006.9

 

Final Results

In the preliminary test, no ignition was observed up to 90 °C. At 90 °C the ignition flame extinguished. The test item has no flash point up to 90 °C, where the ignition flame extinguished.

 

Interpretation of results:
GHS criteria not met
Conclusions:
No flash point up to 90 °C where the ignition flame extinguished.
Executive summary:

A study was conducted according to Regulation (EC) No 440/2008 method A.9, OPPTS 830.6315 and ISO 3679:2004 to determine flash point of the test item using a closed cup method. In the preliminary test, no ignition was observed up to 90 °C. At 90 °C the ignition flame extinguished. This result was confirmed in the main test. Thus, it was concluded that, the test item has no flash point up to 90 °C, where the ignition flame extinguished.

Description of key information

No flash point up to 90 °C where the ignition flame extinguished.

Key value for chemical safety assessment

Additional information

A study was conducted according to Regulation (EC) No 440/2008 method A.9, OPPTS 830.6315 and ISO 3679:2004 to determine flash point of the test item using a closed cup method. In the preliminary test, no ignition was observed up to 90 °C. At 90 °C the ignition flame extinguished. This result was confirmed in the main test. Thus, it was concluded that, the test item has no flash point up to 90 °C, where the ignition flame extinguished.