Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11-July-2017
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
Rosin, reaction products with acrylic acid
EC Number:
280-192-2
EC Name:
Rosin, reaction products with acrylic acid
Cas Number:
83137-13-7
Molecular formula:
N.A. - UVCB substance
IUPAC Name:
Rosin, reaction products with acrylic acid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 646729
- Physical state: yellow to brownish solid
- Expiration date of the lot/batch: 19 November 2018
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: MTDID 28640 immediately melted to a brown liquid and briefly ignited with an orange flame, but no propogation was observed.

Any other information on results incl. tables

MTDID 28640 is classified as not highly flammable.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
MTDID 28640 is not highly flammable by EU Method A.10.
Executive summary:

The flammability of MTDID 28640 was evaluated according to EU method A.10. The sample of MTDID 28640 melted and briefly ignited, but no propagation was observed, thus the chemical is classified as not highly flammable. The test was conducted according to EU guidance and was GLP compliant; therefore the results are considered reliable without restriction.