Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 252-907-8 | CAS number: 36196-44-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Eye irritation
Administrative data
- Endpoint:
- eye irritation, other
- Remarks:
- Standard Draize test
- Type of information:
- (Q)SAR
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- 1. SOFTWARE: ACD Labs/Percepta (2016 Release).
2. MODEL: ACD/Percepta: Eye Irritation
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL:
Structural formula: C18H27N3O9S3
Structural codes:
a. SMILES: O=C(OCCn1c(=O)n(c(=O)n(CCOC(=O)CCS)c1=O)CCOC(=O)CCS)CCS
b. InChI: InChI=1S/C18H27N3O9S3/c22-13(1-10-31)28-7-4-19-16(25)20(5-8-29-14(23)2-11-32)18(27)21(17(19)26)6-9-30-15(24)3-12-33/h31-33H,1-12H2
c. Other structural representation: mol file used and included in the test material information.
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
- Defined endpoint: Eye irritation/corrosion
- Unambiguous algorithm: Binomial PLS probabilistic model supplemented by an expert system that identifies structural alerts relevant to irritating properties of compounds (see attached QMRF for further details).
- Defined domain of applicability: Detailed structural and/or response limits of the applicability domain are not defined. However, for each prediction, a list of all the rules (alerts) applicable to the calculation of irritation potential of the target molecule is provided, as well as the percentage of training set chemicals containing these alerts and exhibiting moderate or stronger eye irritation. In addition, the software displays up to five most similar structures from the training set along with experimental results.
- Appropriate measures of goodness-of-fit and robustness and predictivity: Please see attached QMRF.
- Mechanistic interpretation: The structural alerts used for classifying chemicals were derived from existing mechanistic knowledge. Fragmental descriptors used in the analysis have been predefined to represent certain features of the compounds known to be related to their eye irritating properties, e.g. high acidity, basicity, electrophilicity, etc.
5. APPLICABILITY DOMAIN
For the target TEMPIC, one structural analogue was identified in the training set, suggesting that the target is partially included in the applicability domain of the model. No structural alerts for eye irritation were identified.
-descriptor domain: not applicable.
-structural fragment domain: not applicable.
-mechanism domain: not applicable.
Please see attached QPRF for structural analogues and further details.
6. ADEQUACY OF THE RESULT
TEMPIC was predicted negative for eye irritation/corrosion in standard rabbit Draize test based on a predicted probability to cause severe/moderate eye irritation equal to 0.13. The prediction was assessed as moderately reliable. This QSAR prediction indicated an absence of eye irritation/corrosion potential for the target TEMPIC and could be used in a weight of evidence approach to support the conclusion for no classification.
This negative eye irritation QSAR prediction was assessed as adequate for regulatory purposes.
Data source
Reference
- Reference Type:
- other: Software
- Title:
- Unnamed
- Year:
- 2 012
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- other: REACH Guidance on QSARs R.6 (2008)
- Principles of method if other than guideline:
- - Software tool(s) used including version: ACD/Labs (2016 release)
- Model(s) used: ACD/Percepta Eye Irritation
- Model description: see field 'Justification for type of information' and 'Attached justification'
- Justification of QSAR prediction: see field 'Justification for type of information' and 'Attached justification'
Test material
- Reference substance name:
- (2,4,6-trioxo-1,3,5-triazine-1,3,5(2H,4H,6H)-triyl)triethane-2,1-diyl tris(3-mercaptopropionate)
- EC Number:
- 252-907-8
- EC Name:
- (2,4,6-trioxo-1,3,5-triazine-1,3,5(2H,4H,6H)-triyl)triethane-2,1-diyl tris(3-mercaptopropionate)
- Cas Number:
- 36196-44-8
- Molecular formula:
- C18H27N3O9S3
- IUPAC Name:
- 2-[2,4,6-trioxo-3,5-bis({2-[(3-sulfanylpropanoyl)oxy]ethyl})-1,3,5-triazinan-1-yl]ethyl 3-sulfanylpropanoate
- Test material form:
- liquid: viscous
Constituent 1
- Specific details on test material used for the study:
- SMILES: O=C(OCCn1c(=O)n(c(=O)n(CCOC(=O)CCS)c1=O)CCOC(=O)CCS)CCS
InChI=1S/C18H27N3O9S3/c22-13(1-10-31)28-7-4-19-16(25)20(5-8-29-14(23)2-11-32)18(27)21(17(19)26)6-9-30-15(24)3-12-33/h31-33H,1-12H2
Test animals / tissue source
- Species:
- rabbit
Results and discussion
In vivo
Results
- Irritation parameter:
- other: Probability to cause severe/moderate eye irritation = 0.13
- Remarks on result:
- no indication of irritation
- Remarks:
- Based on QSAR prediction
Any other information on results incl. tables
The uncertainty of the prediction was evaluated considering the following aspects: i) positive predicted probability; ii) identified structural alerts; ii) similarity of the target compound to the training set and consistency of experimental values for similar compounds.
Limited uncertainty was associated with the negative eye irritation prediction generated for the target TEMPIC based on the following consideration: one structural analogue with a negative experimental value (i.e. not irritating) was identified in the training set.
Overall, the eye irritation prediction was assessed as moderately reliable.
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Remarks:
- This QSAR prediction could be used in a weight of evidence approach to support the conclusion for no classification.
- Conclusions:
- TEMPIC was predicted negative for eye irritation/corrosion in standard rabbit Draize test based on a predicted probability to cause severe/moderate eye irritation equal to 0.13. The prediction was assessed as moderately reliable. This QSAR prediction indicated absence of eye irritation/corrosion potential for the target TEMPIC and could be used in a weight of evidence approach to support the conclusion for no classification.
- Executive summary:
This study was designed to generate estimated in silico (non-testing) data of eye irritation for TEMPIC. A reliability score of 2 was assigned, since results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation/justification.
The eye irritation model implemented in ACD/Percepta (2016 Release) was employed, which estimates the potential of a chemical to cause eye irritation in a standard rabbit Draize test. The cut-off value for positive/negative eye irritation predictions is 0.5.
ACD/Percepta eye irritation model predicted the target as an eye irritant, based on a probability to cause severe/moderate eye irritation equal to 0.13. The uncertainty of the prediction was evaluated considering the following aspects: i) positive predicted probability; ii) identified structural alerts; ii) similarity of the target compound to the training set and consistency of experimental values for similar compounds. A limited uncertainty was associated with the negative eye irritation prediction generated for the target TEMPIC, since one structural analogue with a negative experimental value (i.e. not irritating) was identified in the training set.
Overall, the negative eye irritation prediction was assessed as moderately reliable and adequate for regulatory purposes.
.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer