Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 to 20 Jul 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)
Remarks:
Certificat de conformite aux bonnes pratiques de laboratoire selon les directives 2004/9/CE et 2004/10/CE
Auto-ignition temperature:
> 601 °C
Atm. press.:
978 hPa

Preliminary test

 

 

 

Injection No.

Volume of test item injected in the oven (µL)

 

Temperature

(°C)

 

Auto-ignition

Maximal temperature of the air recorded in the center of the test flask after auto-ignition (°C)

 

Atm pressure (kPa)

 

Relative humidity (%)

Observed

Corrected

Y / N

Lag (s)

Observed

Corrected

1

70

104

104

N

/

/

/

97.6

55

2

70

150

150

N

/

/

/

98.0

52

3

70

201

201

N

/

/

/

98.0

52

4

70

247

247

N

/

/

/

98.0

53

5

70

295

295

N

/

/

/

98.0

54

6

70

347

347

N

/

/

/

98.0

53

7

70

403

403

N

/

/

/

98.0

52

8

70

453

453

N

/

/

/

98.0

52

9

70

501

501

N

/

/

/

98.0

52

10

70

554

554

N

/

/

/

98.0

51

11

90

564

564

N

/

/

/

98.0

48

12

110

564

564

N

/

/

/

98.0

45

13

130

564

564

N

/

/

/

98.0

43

14

150

564

564

N

/

/

/

98.0

43

15

170

564

564

N

/

/

/

97.9

43

16

190

564

564

N

/

/

/

97.8

43

 

This first part was performed with an oven which did not reach 600 °C. Complementary assays were made with another oven.

 

 

 

Injection No.

Volume of test item injected in the oven (µL)

 

Temperature

(°C)

 

Auto-ignition

Maximal temperature of the air recorded in the center of the test flask after auto-ignition (°C)

 

Atm pressure (kPa)

 

Relative humidity (%)

Observed

Corrected

Y / N

Lag (s)

Observed

Corrected

1

70

600

601

N

/

/

/

97.8

37

2

90

600

601

N

/

/

/

97.8

37

3

110

600

601

N

/

/

/

97.8

37

4

130

600

601

N

/

/

/

97.8

38

5

150

600

601

N

/

/

/

97.8

38

6

170

600

601

N

/

/

/

97.8

39

7

190

600

601

N

/

/

/

97.8

39

Main test

Taking into account the results obtained during the preliminary assay, no main test was performed.

 

Conclusion

Only a preliminary test was performed: No auto-ignition temperature was observed up to 601 °C (corrected value).

Conclusions:
No auto-ignition temperature was observed up to 601 °C at 980 hPa in a reliable study conducted according to an appropriate test protocol.

Description of key information

Trichloro(4-methylphenyl)silane: > 601 °C at 980 hPa (EU method A.15)

Key value for chemical safety assessment

Additional information